TA6000

Integrated system

TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER
Included
ENCLOSURE
Not specified
NOMINAL ENERGY
10.24–20.48 kWh
AC CONFIGURATION
120 V US / 230 V EU AC options
Start your project ↗

Specifications

Model / configurationEnergy (kWh)AC options (kW)
TA6000-M210.246–10
TA6000-M315.366–12
TA6000-M420.486–12

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

ModelDimensions (mm)Approx. kg
TA6000-M2590 × 570 × 1880 / W × D × H244
TA6000-M3590 × 570 × 1880 / W × D × H286
TA6000-M4590 × 570 × 1880 / W × D × H328

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

Choose for the equipment room, not a national average.

A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration.

Temperature:
Operating −20 to 60 °C
ENCLOSURE
Not specified
01

Cooler winter location · garage or outbuilding

Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home.

Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging.

Can the battery position fall below 0 °C during charging?
  • Will the selected heating and charging protections be confirmed for this exact model?
  • Does the location remain dry when cold equipment meets warmer air?
02

Basement utility room · dry and accessible

A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable.

The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space.

Is there damp, condensation or a known water-entry route?
  • Are ventilation and service access clear of storage items?
  • Is this a new integrated installation or an addition to an existing inverter?
03

Warmer summer region · indoor heat

Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions.

Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it.

Does the room accumulate afternoon or roof heat?
  • What are the exact model's temperature and output derating requirements?
  • Can the proposed mounting position maintain the required cooling space?
Specifications
  • Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication.
  • Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging.
  • IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

Original terminal labels
Original terminal labelsConnection panel labelled for load, grid, optional generator, PV and communication.
Terminal panel close-up
Terminal panel close-upClose-up of the cabinet terminal panel.
Original breaker labels
Original breaker labelsBattery, PV1, PV2, load and grid breakers in the illustrated compartment.
Breaker compartment close-up
Breaker compartment close-upCircuit breakers within the cabinet's breaker compartment.
Upper cabinet and service bay
Upper cabinet and service bayUpper cabinet compartment with the inverter and connection area.
Cell assembly detail
Cell assembly detailBattery cell tops in a partial internal illustration.

Know your interfaces.

Power connections

Load Output
Output position identified as Load Output in the brochure.
Grid Input
Connection position identified as Grid Input.
Generator Input (optional)
The generator input is explicitly marked optional in the original callout.
PV Input
PV connection area identified by the original callout.
PV1 Input Breaker
Breaker identified for PV1 Input.
PV2 Input Breaker
Breaker identified for PV2 Input.

Communication

Communication Port
Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

Controls & indicators

Battery Breaker
Breaker labelled for the battery section.
Load Breaker
Breaker identified for the load connection.
Grid Breaker
Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16