EU 230 V

Integrated system

EU 230 V.

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

INVERTER
Included
ENCLOSURE
IP21
NOMINAL ENERGY
10.24 / 16.076 kWh
AC CONFIGURATION
230 V AC / 50 or 60 Hz
Start your project ↗

Specifications

Model / configurationEnergy (kWh)Rated AC (kW)
6.2K-10/16KWH-EU10.246.2
6.2K-10/16KWH-EU16.0766.2
12K-16KWH-EU16.07612

6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation.

ModelDimensions (mm)Approx. kg
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H105
6.2K-10/16KWH-EU552 × 254 × 1210 / L × W × H130
12K-16KWH-EU552 × 254 × 1210 / L × W × H130

Communication: USB / RS485 / dry contact
Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C

Choose for the equipment room, not a national average.

A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration.

Temperature:
Charge 0 to 55 °C; discharge −20 to 55 °C
ENCLOSURE
IP21
01

Cooler winter location · garage or outbuilding

Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home.

Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging.

Can the battery position fall below 0 °C during charging?
  • Will the selected heating and charging protections be confirmed for this exact model?
  • Does the location remain dry when cold equipment meets warmer air?
02

Basement utility room · dry and accessible

A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable.

The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space.

Is there damp, condensation or a known water-entry route?
  • Are ventilation and service access clear of storage items?
  • Is this a new integrated installation or an addition to an existing inverter?
03

Warmer summer region · indoor heat

Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions.

Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it.

Does the room accumulate afternoon or roof heat?
  • What are the exact model's temperature and output derating requirements?
  • Can the proposed mounting position maintain the required cooling space?
Specifications
  • Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication.
  • Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging.
  • IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability.

PRODUCT DETAIL / ORIGINAL LITERATURE

Every side. Every connection.

Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail.

Original numbered interface map
Original numbered interface mapNumbered map of the AC, battery, PV and communication connections.
AC and battery connection side
AC and battery connection sideAC and battery connection side with cooling fans and the battery breaker.
AC and battery upper detail
AC and battery upper detailUpper AC connection area, cooling fans and BAT terminals.
PV and communication side
PV and communication sidePV and communication side, including the battery communication ports.
PV and communication upper detail
PV and communication upper detailVentilation grille above the PV and communication connection area.

Know your interfaces.

Power connections

AC input / output
The AC connection identified by number 1 in the original map.
AC input breaker
Breaker labelled for the AC input.
BAT+ / BAT-
Positive and negative battery terminals, as labelled in the source.
PV input
Input identified for the PV connection.

Communication

Parallel communication port
Communication connection labelled for parallel operation; configuration availability must be confirmed separately.
Dry contact control
Control interface labelled as dry contact in the brochure.
RS485 / BMS communication port
The communication connection named RS485/BMS in the original label.
Wi-Fi port
Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation.
USB communication port
Communication interface labelled USB.
Battery communication ports
The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs.

Controls & indicators

Battery breaker
Breaker identified for the battery section.

Source: EU 230 V product sheet · PDF page 1