# ELVORKA · Deutschland > Residential battery-only and integrated energy storage. Public contact: eric@elvorka.com. The United States English edition is the main website. Country editions describe installation context; they do not establish local stock, offices, certification or grid approval. Product facts follow supplied literature. Scenes are illustrations, not customer-installation evidence. ## Deutsch · de-DE - [Heimspeicher. Klar geplant .](https://de.elvorka.com/de/index.md): https://de.elvorka.com/de/ - [TR Pro.](https://de.elvorka.com/de/products/tr-pro/index.md): https://de.elvorka.com/de/products/tr-pro/ - [EU 230 V.](https://de.elvorka.com/de/products/eu-230v/index.md): https://de.elvorka.com/de/products/eu-230v/ - [HP Ultra.](https://de.elvorka.com/de/products/hp-ultra/index.md): https://de.elvorka.com/de/products/hp-ultra/ - [TA6000.](https://de.elvorka.com/de/products/ta6000/index.md): https://de.elvorka.com/de/products/ta6000/ - [TR standard.](https://de.elvorka.com/de/products/tr-standard/index.md): https://de.elvorka.com/de/products/tr-standard/ - [HP K.](https://de.elvorka.com/de/products/hp-k/index.md): https://de.elvorka.com/de/products/hp-k/ - [TB rack.](https://de.elvorka.com/de/products/tb-rack/index.md): https://de.elvorka.com/de/products/tb-rack/ - [Heimspeicher besser verstehen.](https://de.elvorka.com/de/blog/index.md): https://de.elvorka.com/de/blog/ - [Einblicke in die ELVORKA Produktwelt.](https://de.elvorka.com/de/news/index.md): https://de.elvorka.com/de/news/ - [Wie viel Batteriespeicher braucht Ihr Zuhause?](https://de.elvorka.com/de/blog/battery-capacity/index.md): https://de.elvorka.com/de/blog/battery-capacity/ - [Den Batterieplatz vor der Installation auswählen.](https://de.elvorka.com/de/blog/installation-environment/index.md): https://de.elvorka.com/de/blog/installation-environment/ - [Die internationale ELVORKA Produktübersicht ist online.](https://de.elvorka.com/de/news/product-collection/index.md): https://de.elvorka.com/de/news/product-collection/ - [Originalansichten und Anschlussinformationen leichter finden.](https://de.elvorka.com/de/news/technical-library/index.md): https://de.elvorka.com/de/news/technical-library/ - [Heimspeicher. Klar beschrieben.](https://de.elvorka.com/de/about/index.md): https://de.elvorka.com/de/about/ - [Klare Quellen. Erkennbare Grenzen.](https://de.elvorka.com/de/sources/index.md): https://de.elvorka.com/de/sources/ - [Planen wir Ihr Speicherprojekt.](https://de.elvorka.com/de/contact/index.md): https://de.elvorka.com/de/contact/ ## English · en-DE - [Home storage. Clearly planned .](https://de.elvorka.com/en/index.md): https://de.elvorka.com/en/ - [TR Pro.](https://de.elvorka.com/en/products/tr-pro/index.md): https://de.elvorka.com/en/products/tr-pro/ - [EU 230 V.](https://de.elvorka.com/en/products/eu-230v/index.md): https://de.elvorka.com/en/products/eu-230v/ - [HP Ultra.](https://de.elvorka.com/en/products/hp-ultra/index.md): https://de.elvorka.com/en/products/hp-ultra/ - [TA6000.](https://de.elvorka.com/en/products/ta6000/index.md): https://de.elvorka.com/en/products/ta6000/ - [TR standard.](https://de.elvorka.com/en/products/tr-standard/index.md): https://de.elvorka.com/en/products/tr-standard/ - [HP K.](https://de.elvorka.com/en/products/hp-k/index.md): https://de.elvorka.com/en/products/hp-k/ - [TB rack.](https://de.elvorka.com/en/products/tb-rack/index.md): https://de.elvorka.com/en/products/tb-rack/ - [A clearer view of home storage.](https://de.elvorka.com/en/blog/index.md): https://de.elvorka.com/en/blog/ - [Inside the ELVORKA collection.](https://de.elvorka.com/en/news/index.md): https://de.elvorka.com/en/news/ - [How much battery storage does your home need?](https://de.elvorka.com/en/blog/battery-capacity/index.md): https://de.elvorka.com/en/blog/battery-capacity/ - [Choose the battery location before installation.](https://de.elvorka.com/en/blog/installation-environment/index.md): https://de.elvorka.com/en/blog/installation-environment/ - [The international ELVORKA product collection is available online.](https://de.elvorka.com/en/news/product-collection/index.md): https://de.elvorka.com/en/news/product-collection/ - [Original product views and interface notes are now easier to explore.](https://de.elvorka.com/en/news/technical-library/index.md): https://de.elvorka.com/en/news/technical-library/ - [Home storage. Clearly specified.](https://de.elvorka.com/en/about/index.md): https://de.elvorka.com/en/about/ - [Clear sources. Visible limits.](https://de.elvorka.com/en/sources/index.md): https://de.elvorka.com/en/sources/ - [Let’s plan your storage project.](https://de.elvorka.com/en/contact/index.md): https://de.elvorka.com/en/contact/ ## Structured reference - [Product catalogue](https://de.elvorka.com/data/product-catalogue.json): exact model data; source qualifications and assumptions kept separate. - [Sitemap](https://de.elvorka.com/sitemap.xml): canonical public HTML pages. --- # Heimspeicher. Klar geplant . HEIMSPEICHER / DEUTSCHLAND # Heimspeicher. Klar geplant . Integrierte Systeme und LFP-Batterien für eine sorgfältig geplante Hausinstallation. Vergleichen Sie Batterie, Wechselrichteranbindung und Anschlussdetails vor der Konfigurationswahl. [Produkte entdecken](https://de.elvorka.com/de/#products)[Passenden Speicher finden](https://de.elvorka.com/de/#planner) Ein Zuhause. Ein durchdachtes System. Integrierter Speicher oder Batterie für Ihren Wechselrichter. ![EU 230 V — INSTALLATIONSILLUSTRATION](https://de.elvorka.com/assets/optimized/1a28066966a58cf7-1536-q92.webp) INSTALLATIONSILLUSTRATION 01 / 03 INSTALLATIONSILLUSTRATION [WECHSELRICHTER INTEGRIERT EU 230 V Batterie + Wechselrichter integriert](https://de.elvorka.com/de/#products) WENIGER PLATZBEDARF. MEHR MÖGLICHKEITEN. 07 Produktfamilien 29 Aufgeführte Konfigurationen 5.12–48 kWh Nennenergie der Produktreihe [Produktrundgang](https://de.elvorka.com/de/#product-tour) Produktrundgang ## Ein Zuhause. Ein durchdachtes System. Integrierter Speicher oder Batterie für Ihren Wechselrichter. HEIMSPEICHER / DEUTSCHLAND LFP ![Installationsillustration einer TR Pro Batterie im Technikbereich eines Wohnhauses.](https://de.elvorka.com/assets/optimized/20e2f83648685da5-1536-q92.webp) HEIMBATTERIE-INSTALLATION Produkt-Szenenillustration [TR PRO / WANDSPEICHER ![TR Pro LFP-Wandbatterie ohne Logo](https://de.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp) Speicher. An seinem Platz. 10.24 / 16.076 kWh Nennenergie 51.2 V DC-NENNSPANNUNG IP66 GEHÄUSE](https://de.elvorka.com/de/#products) [Alle Produkte](https://de.elvorka.com/de/#products) 01 ZWEI WEGE ZUM SPEICHER ## Ihre Anlage ist der Ausgangspunkt. Neue Anlage oder vorhandener Wechselrichter. Wählen Sie Ihren Ausgangspunkt. [INTEGRIERTE SYSTEME ### Von Anfang an alles in einem. Batterie und Wechselrichter in einem System. Eine abgestimmte Basis für eine neue Anlage. ALL-IN-ONE ENTDECKEN 6 aufgeführte Konfigurationen](https://de.elvorka.com/de/#products) [BATTERIESYSTEME ### Ihr Wechselrichter. Mehr Möglichkeiten. LFP-Speicher für Wand-, Stapel- oder Rackmontage. Spannung abstimmen und Kompatibilität prüfen. BATTERIEN ENTDECKEN 23 aufgeführte Konfigurationen](https://de.elvorka.com/de/#products) TR PRO / MATERIAL & FORM 01 — GEHÄUSE / VORDERANSICHT PRODUKTDETAIL 03 GENAUER HINSEHEN ## Details für Ihre Planung. Beginnen Sie bei der Zellchemie. Prüfen Sie die Spannung. Wählen Sie das Gehäuse. Eine gute Installation setzt klare Produktkenntnisse voraus. LiFePO₄ LFP-Batteriechemie 51.2 V TR Pro DC-Nennspannung IP66 TR Pro Gehäuseschutzart CAN / RS485 Kommunikationsschnittstellen [TR Pro Spezifikationen ansehen](https://de.elvorka.com/de/#products) ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. 02 DIE PRODUKTREIHE ## Speicher. Klar spezifiziert. Sieben Familien. Drei Installationsformate. Vergleichen Sie die entscheidenden Details. 3 Produktfamilien ### TR Pro. Wandmontiert. Durchdacht gestaltet. 10.24 / 16.076 kWh LFP-Wandbatterie mit drei spezifizierten Modellen und IP66-Gehäuse. Mit einem kompatiblen externen Wechselrichter kombinieren. [Alle Produktdetails entdecken ↗](https://de.elvorka.com/de/products/tr-pro/) ### EU 230 V. Ein integrierter Ausgangspunkt. 10.24 / 16.076 kWh Ein integriertes System aus Wechselrichter und 51.2 V LFP-Batterie. Drei aufgeführte Leistungs- und Energiekonfigurationen mit 6.2 oder 12 kW AC-Nennleistung. [Alle Produktdetails entdecken ↗](https://de.elvorka.com/de/products/eu-230v/) ### HP Ultra. Speicher mit Raum zum Wachsen. 8–48 kWh Ein modularer LFP-Batteriestapel aus Aluminiumlegierung. Sechs spezifizierte Konfigurationen von 8 bis 48 kWh zur Integration mit einem kompatiblen externen Wechselrichter. [Alle Produktdetails entdecken ↗](https://de.elvorka.com/de/products/hp-ultra/) Gewählte Konfiguration, Wechselrichterkompatibilität, Projektanforderungen und Lieferbedingungen vor der Bestellung bestätigen. Ihre Anlage entscheidet. Reine Batterieprodukte benötigen einen kompatiblen externen Wechselrichter. [Vollständigen Katalog herunterladen](https://de.elvorka.com/downloads/ELVORKA_de_de_Product_Guide.pdf) PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Mehr als die wichtigsten Kennzahlen. Entdecken Sie Originalansichten, beschriftete Schnittstellen und Details jeder Familie. 05 DAS WESENTLICHE KENNEN ## Entdecken Sie Ihre Notstromplanung. Beginnen Sie mit den Verbrauchern, die weiterlaufen sollen. Variieren Sie Last und Batteriekapazität für eine unverbindliche Abschätzung der Überbrückungszeit. Batterieenergie wird gemessen in kWh . Geräteleistung wird gemessen in kW . Ihr Wechselrichter muss die Last unterstützen. Wechselrichter bei All-in-one-Systemen integriert; bei reinen Batterieprodukten extern. NOTSTROM-RECHNER IHRE SCHÄTZUNG Watt / kW Batteriekapazität 10.24 kWh Mittlere Leistung wichtiger Verbraucher 1.0 kW 0.2 kW 5.0 kW Planungsbeispiele, keine gemessenen Verbräuche oder Laufzeitgarantien. Anlaufstrom, ersatzstromfähige Stromkreise und AC-Ausgang des Wechselrichters bestätigen. GESCHÄTZTE ÜBERBRÜCKUNGSZEIT 8.3 Stunden So wird die Schätzung berechnet Batterie-Nennkapazität × 90% angenommene nutzbare Entladetiefe × 90% angenommener Wechselrichterwirkungsgrad ÷ mittlere Last. Dies sind Planungsannahmen, keine garantierten Produktwerte. Die tatsächliche Dauer hängt von nutzbarer Energie, Temperatur, Alterung, Eigenverbrauch und Lastwechseln ab. Anlaufströme und Wechselrichtergrenzen sind separat zu prüfen. [In meine Planung übernehmen](https://de.elvorka.com/de/#enquiry) UNSERE PRODUKTE / ZUHAUSE ### Ein klarer Plan für Ihren Heimspeicher. Für Hauseigentümer und Installationsfachleute bei Projekten in Deutschland: Beginnen Sie mit der bestehenden Anlage, dem verfügbaren Platz und den zu versorgenden Verbrauchern. Dies sind Planungsszenarien, keine abgeschlossenen lokalen Kundenreferenzen. EU 230 V / WECHSELRICHTER INTEGRIERT #### Ein neues integriertes System planen. Vergleichen Sie All-in-one-Speicher mit bereits integriertem Wechselrichter. Legen Sie die benötigte AC-Konfiguration fest und lassen Sie die Installationsplanung für das Projekt prüfen. HP ULTRA / NUR BATTERIE #### Zum vorhandenen Wechselrichter passend wählen. Gleichen Sie die 51.2 V- und Hochvoltbatterien mit dem DC-Spannungsfenster, der unterstützten Kommunikation und den Betriebseinstellungen Ihres Wechselrichters ab. Reine Batterieprodukte benötigen einen kompatiblen externen Wechselrichter. TR PRO / NUR BATTERIE #### Wichtige Verbraucher festlegen. Erfassen Sie ausgewählte Beleuchtung, Kühlung und Kommunikationsgeräte. Der Watt-Rechner liefert eine unverbindliche Laufzeitschätzung; Ersatzstromfunktion, Stromkreise und Schutzkonzept anschließend mit der Installationsfachkraft prüfen. Installationsillustrationen mit Produkten dieser Reihe. Die Szenen sind Bildkompositionen, keine Fotos abgeschlossener Kundenprojekte. Sichtbare Anordnungen sind beispielhaft; Anschlüsse, Schutz und Abstände richten sich nach dem Installationshandbuch des gewählten Modells und der Standortplanung. 06 IHR SYSTEM VERSTEHEN ## Mit Klarheit entscheiden. [elvorka Produktkatalog Deutsch · PDF · 8 Seiten PDF](https://de.elvorka.com/downloads/ELVORKA_de_de_Product_Guide.pdf) [elvorka Ansichten & Schnittstellen 35 Quellansichten · 7 Familien · Englisches PDF PDF](https://de.elvorka.com/downloads/product-views-and-interfaces.pdf)[Detailbibliothek entdecken Original-Produktansichten, beschriftete Schnittstellen und Quellenangaben.](https://de.elvorka.com/de/#technical-library) [Original-Produktübersicht · PDF auf Englisch ↘](https://de.elvorka.com/downloads/energy-product-collection.pdf) Gute Fragen. Klare Antworten. Beginnen Sie mit Ihrer bestehenden Anlage. Wählen Sie den passenden Speicher. Was ist für ein Heimspeicherprojekt in Deutschland zu bestätigen? Prüfen Sie genaue Produktkonfiguration, AC-Versorgung und Phasenanforderungen, Batteriespannungsbereich, Wechselrichterkommunikation, wichtige Lastkreise und Installationsort. Die landesspezifische Eignung und erforderliche Unterlagen sind für das gewählte Gerät und Projekt zu prüfen; dieser Katalog ist keine Zulassungsbescheinigung. Kann ich eine 51.2 V Batterie an meinen Wechselrichter anschließen? Gleiche Nennspannung allein bestätigt keine Kompatibilität. Der Installateur muss DC-Spannungsfenster, Lade- und Entladestrom, CAN- oder RS485-Protokoll, Firmware und Schutzeinstellungen prüfen. Hochvoltbatterien dürfen nicht an Niedervoltwechselrichter angeschlossen werden. Was ist bei einem Projekt in Deutschland zu prüfen? AC-Versorgung, Phasenanforderungen des Wechselrichters, wichtige Lastkreise und örtliche elektrische Anforderungen prüfen. Die integrierte EU-Reihe nennt 230 V AC und 50 / 60 Hz. TA6000 nennt 120 V US- und 230 V EU-Optionen; die erforderliche Marktausführung festlegen. Notstromkreise und Schutzkonzept müssen vom Installateur geprüft werden. Können diese Batterien im Freien installiert werden? TR Pro und HP Ultra nennen IP66-Gehäuse. Andere Familien haben andere oder optionale Schutzarten. Eine IP-Schutzart ist keine Installationsanleitung: Temperaturgrenzen, Abstände, Witterungsschutz, Belüftung und Installationsvorgaben des gewählten Modells prüfen. Bedeutet mehr Batteriekapazität auch mehr Ausgangsleistung? Nein. Kapazität in kWh bezeichnet gespeicherte Energie. Leistung in kW beschreibt, wie schnell Energie abgegeben werden kann. DC-Batteriewerte und AC-Wechselrichterleistung sind unterschiedlich. Batterie und Wechselrichter müssen Betriebs- und Anlauflasten unterstützen. Wie bestätige ich Preis, Garantie und Verfügbarkeit? Erstellen Sie eine Projektanfrage mit Ort, benötigten Lasten, vorhandenem Wechselrichter und Produktauswahl. Lassen Sie genaue Konfiguration, Angebotswährung, Garantiebedingungen, Installationsumfang, Lieferzeit und Kundendienst schriftlich bestätigen. Kann die Batterie in eine unbeheizte Garage? Erst nach Abgleich von Temperatur, Feuchte und Exposition mit den Vorgaben des genauen Modells. Mehrere Familien nennen Laden ab 0 °C. Heizkonfiguration und Ladeschutz bestätigen; kältere Entladegrenzen erlauben kein entsprechendes Laden. Kann ich eine Wärmepumpe oder einen Elektroherd absichern? Diese Verbraucher separat auslegen. Betriebsleistung und Anlauf können die Planung bestimmen; die Beispiel-Grundlasten enthalten sie nicht. DC-Leistung der Batterie sowie AC-Ausgang und Ersatzstromfähigkeit des Wechselrichters und der Stromkreise prüfen. Bestätigt eine 230 V-Angabe die Eignung für meine Anlage? Nein. AC-Konfiguration, Phasenanordnung, erforderliche Unterlagen, Wechselrichterkompatibilität und Installationsplanung für das konkrete Projekt bestätigen. Der Katalog belegt keine landesspezifische Zulassung. Ihr nächster Schritt ## Ihre Anlage ist der Ausgangspunkt. [01 ### Produkte entdecken Sieben Familien. Drei Installationsformate.](https://de.elvorka.com/de/#products)[02 ### Passenden Speicher finden Beginnen Sie mit den wichtigen Verbrauchern, die weiterlaufen sollen.](https://de.elvorka.com/de/#planner)[03 ### Anfrage vorbereiten Beschreiben Sie Ihr Zuhause.](https://de.elvorka.com/de/#enquiry) IHR NÄCHSTER SCHRITT ## Planen wir Ihr System . Beschreiben Sie Ihr Zuhause. Erstellen Sie eine klare Projektanfrage für Ihren Installateur oder Speicheranbieter. IHR ZUHAUSE. IHRE ENERGIE. [eric@elvorka.com](mailto:eric@elvorka.com) Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. Ihr Name (optional) Projektort * Ihre E-Mail-Adresse Telefon / WhatsApp (optional, mit Ländervorwahl) Unternehmen (optional) Ich plane für Vorhandener Wechselrichter Produktinteresse Was ist Ihnen wichtig? Region und saisonale Exposition Niedrigste / höchste beobachtete Raumtemperatur AC-Versorgung und benötigte Phasenanordnung Ihre Angaben werden für die Prüfung und weitere Bearbeitung durch ELVORKA gespeichert. Bitte keine Passwörter, Ausweisdokumente oder sachfremden sensiblen Informationen eintragen. ELVORKA darf diese Angaben zur Bearbeitung und Beantwortung meiner Projektanfrage verwenden. ELVORKA ## Heimspeicher besser verstehen. Praxisnahe Beiträge zur Speicherkapazität, zu den Bedingungen im Technikraum und zu einer aussagekräftigen Projektanfrage. --- https://de.elvorka.com/de/ ELVORKA · eric@elvorka.com --- # TR Pro. ![TR Pro](https://de.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp) Niedervoltbatterie # TR Pro. LFP-Wandbatterie mit drei spezifizierten Modellen und IP66-Gehäuse. Mit einem kompatiblen externen Wechselrichter kombinieren. WECHSELRICHTER Kompatibler externer Wechselrichter erforderlich GEHÄUSE IP66 NENNENERGIE 10.24 / 16.076 kWh BATTERIESPANNUNG 51.2 V DC-Nennspannung [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | DC-Nennleistung (kW) | | --- | --- | --- | | TR6000WX-Pro | 10.24 | 10 | | TR8500WX-Pro | 16.076 | 10 | | TR8500WX-ProU | 16.076 | 10 | Selbstheizung ist optional. Leistungsangaben gelten batterieseitig für DC; die tatsächliche AC-Leistung hängt vom gewählten Wechselrichter ab. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | TR6000WX-Pro | 802 × 620 × 179 / H × L × D | 95 | | TR8500WX-Pro | 822 × 500 × 250 / H × L × D | 115.5 | | TR8500WX-ProU | 872 × 500 × 250 / H × L × D | 120 | Kommunikation: RS485 / RS232 / CAN; Wi-Fi / Bluetooth Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 60 °C ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 60 °C GEHÄUSE IP66 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Die Abbildung zeigt ein repräsentatives Gehäuse mit Rollen; sie belegt nicht identische Unterteile oder Anschlusspositionen aller Pro-Modelle. Roller bezeichnet ein Rad. Main Circuit Breaker und Battery Switch sind getrennte Quellenbezeichnungen. Inhalt des vollständigen Schalterfotos außerhalb des Druckausschnitts begründet keine zusätzlichen Schnittstellenaussagen. [![Anschlussbeschriftungen auf der Anschlussseite](https://de.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)](https://de.elvorka.com/assets/product-details/tr-pro-terminal-labels.png) Anschlussbeschriftungen auf der Anschlussseite Batterieklemmen, Schalter, Wi-Fi-Antenne und Kommunikationsports an der Gehäuseseite. [![Hauptschutzschalter und Klappgriff](https://de.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)](https://de.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png) Hauptschutzschalter und Klappgriff Hauptschutzschalter und Klappgriff an der gezeigten Gehäuseseite. [![Originale Dreiviertelansicht der Anschlussseite](https://de.elvorka.com/assets/product-details/tr-pro-connection-side.png)](https://de.elvorka.com/assets/product-details/tr-pro-connection-side.png) Originale Dreiviertelansicht der Anschlussseite Anschlussseitenansicht von Gehäuse, Batterieklemmen und Klappgriff. [![Originales schmales Seitenprofil](https://de.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)](https://de.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png) Originales schmales Seitenprofil Schmales Seitenprofil des gezeigten Gehäuses. [![Originalfoto des Stromkreisschalters](https://de.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)](https://de.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png) Originalfoto des Stromkreisschalters Stromkreisschalter mit ON- und OFF-Positionsmarkierungen. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse Batterie-Pluspol Positiver DC-Batterieanschluss auf der Anschlussseite. Batterie-Minuspol Negativer DC-Batterieanschluss auf der Anschlussseite. #### Kommunikation RS485 In der Quelle benannte RS485-Schnittstelle; Pinbelegung und Liste kompatibler Geräte werden nicht angegeben. Wi-Fi-Antenne Mit dem Originalpfeil bezeichnete Wi-Fi-Antenne. CAN In der Quelle benannte CAN-Kommunikationsschnittstelle; Protokollversion und Pinbelegung sind nicht angegeben. RS232 In der Quelle benannte RS232-Kommunikationsschnittstelle; Pinbelegung nicht angegeben. COM1 Als COM1 bezeichneter Anschluss; Funktion und Verdrahtung werden auf dieser Seite nicht ausdrücklich festgelegt. COM0 Als COM0 bezeichneter Anschluss; Funktion und Verdrahtung werden auf dieser Seite nicht ausdrücklich festgelegt. #### Bedienelemente & Anzeigen Pulsierendes Statuslicht Der vordere Statuslichtstreifen wird als Breathing Light bezeichnet. Farbbedeutungen und Betriebslogik sind nicht angegeben. Hauptschutzschalter Hauptschutzschalter, durch Originalpfeil gekennzeichnet. Auslösewerte und Verdrahtung werden hier nicht angegeben. Batterieschalter Batterieschalter ist in der Anschlussansicht separat benannt; ohne modellspezifisches Handbuch nicht mit Main Circuit Breaker gleichsetzen. #### Aufbau & Montage Wandhalterung Mechanische Wandhalterung; keine elektrische Schnittstelle. Rollen Räder am repräsentativen Gehäuse. Die Bezeichnung ist mechanisch und meint keinen Anschluss oder unteren Kommunikationsport. Klappgriff Mechanischer Klappgriff; kein elektrischer Anschluss. Quelle: Residential ESS-Broschüre · PDF-Seite 4 · Druckseiten 7-8 --- https://de.elvorka.com/de/products/tr-pro/ ELVORKA · eric@elvorka.com --- # EU 230 V. ![EU 230 V](https://de.elvorka.com/assets/optimized/ed4fde160f2f91fd-1048-q92.webp) Integriertes System # EU 230 V. Ein integriertes System aus Wechselrichter und 51.2 V LFP-Batterie. Drei aufgeführte Leistungs- und Energiekonfigurationen mit 6.2 oder 12 kW AC-Nennleistung. WECHSELRICHTER Enthalten GEHÄUSE IP21 NENNENERGIE 10.24 / 16.076 kWh AC-KONFIGURATION 230 V AC / 50 oder 60 Hz [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | AC-Nennleistung (kW) | | --- | --- | --- | | 6.2K-10/16KWH-EU | 10.24 | 6.2 | | 6.2K-10/16KWH-EU | 16.076 | 6.2 | | 12K-16KWH-EU | 16.076 | 12 | 6.2 kW AC-Konfigurationen: 1 MPPT und max. PV 6.5 kW. 12 kW AC: 2 MPPT und max. PV 2 × 9 kW. Wi-Fi, Parallelbetrieb und CT-Optionen sind zu bestätigen. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 105 | | 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 | | 12K-16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 | Kommunikation: USB / RS485 / potentialfreier Kontakt Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 55 °C ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 55 °C GEHÄUSE IP21 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Ansichten und Nummerierung stammen ausschließlich aus der bereitgestellten einseitigen EU-Broschüre. Pinbelegungen, Kabeldimensionierung, Verdrahtungsabläufe und vollständige Außenansichten fehlen. Die Auflösung der seitlichen Originalbilder ist begrenzt. Die gerenderte Übersicht verbessert die ursprünglichen Vektorbeschriftungen, nicht die fotografischen Details. [![Originale nummerierte Schnittstellenübersicht](https://de.elvorka.com/assets/product-details/eu-interface-map.png)](https://de.elvorka.com/assets/product-details/eu-interface-map.png) Originale nummerierte Schnittstellenübersicht Nummerierte Übersicht der AC-, Batterie-, PV- und Kommunikationsanschlüsse. [![AC- und Batterieanschlussseite](https://de.elvorka.com/assets/product-details/eu-ac-side-full.png)](https://de.elvorka.com/assets/product-details/eu-ac-side-full.png) AC- und Batterieanschlussseite AC- und Batterieanschlussseite mit Kühllüftern und Batterieschutzschalter. [![Oberes Detail der AC- und Batterieanschlüsse](https://de.elvorka.com/assets/product-details/eu-ac-side-upper.png)](https://de.elvorka.com/assets/product-details/eu-ac-side-upper.png) Oberes Detail der AC- und Batterieanschlüsse Oberer AC-Anschlussbereich, Kühllüfter und BAT-Klemmen. [![PV- und Kommunikationsseite](https://de.elvorka.com/assets/product-details/eu-pv-side-full.png)](https://de.elvorka.com/assets/product-details/eu-pv-side-full.png) PV- und Kommunikationsseite PV- und Kommunikationsseite einschließlich der Batterie-Kommunikationsports. [![Oberes Detail der PV- und Kommunikationsseite](https://de.elvorka.com/assets/product-details/eu-pv-side-upper.png)](https://de.elvorka.com/assets/product-details/eu-pv-side-upper.png) Oberes Detail der PV- und Kommunikationsseite Lüftungsgitter oberhalb des PV- und Kommunikationsanschlussbereichs. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse AC-Eingang / -Ausgang Der in der Originalübersicht mit 1 bezeichnete AC-Anschluss. AC-Eingangsschutzschalter Für den AC-Eingang bezeichneter Schutzschalter. BAT+ / BAT- Positive und negative Batterieklemmen gemäß Quellenbeschriftung. PV-Eingang Für den PV-Anschluss bezeichneter Eingang. #### Kommunikation Parallel-Kommunikationsport Für Parallelbetrieb bezeichneter Kommunikationsanschluss; die verfügbare Konfiguration muss separat bestätigt werden. Steuerung über potentialfreien Kontakt In der Broschüre als Dry Contact bezeichnete Steuerschnittstelle. RS485 / BMS-Kommunikationsport In der Originalbeschriftung als RS485/BMS benannter Kommunikationsanschluss. Wi-Fi-Port Als Wi-Fi bezeichneter Port; die Quellspezifikation nennt Wi-Fi als zu bestätigende Option. USB-Kommunikationsport Als USB bezeichnete Kommunikationsschnittstelle. Batterie-Kommunikationsports Die Quelle verweist mit Nummer 11 auf drei runde Öffnungen. Diese werden nicht als AC-Leistungseingänge bezeichnet. #### Bedienelemente & Anzeigen Batterieschutzschalter Für den Batterieteil bezeichneter Schutzschalter. Quelle: EU 230 V Produktblatt · PDF-Seite 1 --- https://de.elvorka.com/de/products/eu-230v/ ELVORKA · eric@elvorka.com --- # HP Ultra. ![HP Ultra](https://de.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp) Hochvoltbatterie # HP Ultra. Ein modularer LFP-Batteriestapel aus Aluminiumlegierung. Sechs spezifizierte Konfigurationen von 8 bis 48 kWh zur Integration mit einem kompatiblen externen Wechselrichter. WECHSELRICHTER Kompatibler externer Wechselrichter erforderlich GEHÄUSE IP66 / Aluminiumlegierung NENNENERGIE 8–48 kWh BATTERIESPANNUNG Gewählte Konfiguration bestätigen [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | Max. DC (kW) | | --- | --- | --- | | HP Ultra-8.0 | 8 | 4 | | HP Ultra-16.0 | 16 | 8 | | HP Ultra-24.0 | 24 | 12 | | HP Ultra-32.0 | 32 | 16 | | HP Ultra-40.0 | 40 | 20 | | HP Ultra-48.0 | 48 | 24 | Systemspannung und Wechselrichterkompatibilität für die gewählte Kapazität bestätigen. Boden- oder Wandmontage ist aufgeführt. Zusätzliche Module erfordern eine Systemprüfung. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 | | HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 | | HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 | | HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 | | HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 | | HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 | Kommunikation: CAN / RS485 / Wi-Fi / Bluetooth Temperatur: Gewählte Konfiguration bestätigen ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Gewählte Konfiguration bestätigen GEHÄUSE IP66 / Aluminiumlegierung 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Nur sechs spezifizierte Konfigurationen mit 8-48kWh. Die Einführungsbilder zeigen einen unbeschrifteten repräsentativen Stapel; Unterseite, vollständige installierte Rückseite, Pinbelegung oder Aktivierungsschnittstelle fehlen. DC-Pole/Schutzschalter/Kühlkörper und Kommunikation/Parallel/GND liegen auf verschiedenen gezeigten Seiten. Kleine Originalzeichnungen sind keine hochauflösenden Produktfotos. Die allgemeinere Überschrift 8.0-128.0 benennt keine weiteren einzeln spezifizierten Modelle. [![DC-/Kühlkörperseite – Originalbeschriftungen](https://de.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://de.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png) DC-/Kühlkörperseite – Originalbeschriftungen DC-Seitenansicht mit Schalter, Batterieklemmen, DC-Schutzschalter und Wärmeableitplatte. [![Kommunikations- und Parallelanschlussseite – Originalbeschriftungen](https://de.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://de.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png) Kommunikations- und Parallelanschlussseite – Originalbeschriftungen Kommunikationsseitige Beschriftungen für Wechselrichterverbindungen, Backup-Kommunikation, BMS-Debugging, parallele COM1/COM2 und GND. [![Detail der Kommunikationsseite (teilweise Schrägansicht)](https://de.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://de.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png) Detail der Kommunikationsseite (teilweise Schrägansicht) Schrägdetail des kommunikationsseitigen Anschlussbereichs am Stapel. [![Moduloberseite / Kontaktflächen](https://de.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://de.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png) Moduloberseite / Kontaktflächen Batteriemoduloberseite und Kontaktflächen. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse Pluspol Durch die ursprüngliche Bezugslinie auf der elektrischen Seite gekennzeichneter Plusanschluss. Minuspol Durch die ursprüngliche Bezugslinie auf der elektrischen Seite gekennzeichneter Minusanschluss. #### Kommunikation Bluetooth/WIFI-Antenne Antennenbeschriftung im oberen Kommunikationsbereich. Backup Com Die Broschüre nennt diesen Anschluss Backup Com, erläutert seine genaue Aufgabe jedoch nicht. INV CAN/RS485 Com Der in der Originalzeichnung mit INV bezeichnete CAN/RS485-Kommunikationsanschluss. Parallel COM1 Erste Parallel-Kommunikationsbezeichnung im unteren Bereich der gezeigten Schnittstellenseite. Parallel COM2 Zweite Parallel-Kommunikationsbezeichnung im unteren Bereich der gezeigten Schnittstellenseite. #### Bedienelemente & Anzeigen Schalter In der DC-Seitenansicht bezeichneter Schalter; die genaue Schaltfunktion wird nicht angegeben. DC-Schutzschalter DC-Schutzschalter auf der elektrischen/Kühlkörperseite. Pulsierendes Statuslicht Lichtstreifen am oberen vorderen Bereich der schrägen Konstruktionsansicht. #### Aufbau & Montage Aluminium-Wärmeableitplatte In der schmalen elektrischen Seitenansicht bezeichnete Aluminium-Wärmeableitplatte. Wandhalterung Halterungen auf der Ansicht der Lüftungsseite. PDU PDU bezeichnet die obere Einheit in der Bauteilhierarchie; die Broschüre erläutert die Abkürzung nicht. Modul Wiederholte Batteriebereiche unterhalb der oberen PDU. Sockel Sockel am unteren Ende des gezeigten Stapels. BMS-Debugging-Schnittstelle In der Kommunikationsansicht bezeichnete BMS-Debugging-Schnittstelle. Druckentlastungsventil In der schrägen Kommunikationsansicht bezeichnetes Druckentlastungsbauteil. GND Mit GND bezeichneter Erdungsanschluss unten auf der Schnittstellenseite. Quelle: Residential ESS-Broschüre · PDF-Seite 5 · Druckseiten 9-10 --- https://de.elvorka.com/de/products/hp-ultra/ ELVORKA · eric@elvorka.com --- # TA6000. ![TA6000](https://de.elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp) Integriertes System # TA6000. Batterie und Wechselrichter in einem Gehäuse, mit PV-Eingang und drei spezifizierten Speicherkonfigurationen. Die AC-Ausgangsoptionen hängen von der gewählten Konfiguration ab. WECHSELRICHTER Enthalten GEHÄUSE Nicht angegeben NENNENERGIE 10.24–20.48 kWh AC-KONFIGURATION 120 V US / 230 V EU AC-Optionen [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | AC-Optionen (kW) | | --- | --- | --- | | TA6000-M2 | 10.24 | 6–10 | | TA6000-M3 | 15.36 | 6–12 | | TA6000-M4 | 20.48 | 6–12 | Passende AC-Marktspannung und 50 / 60 Hz-Option festlegen. PV-Eingang: 11 kW bei M2; 11–13.2 kW bei M3/M4. Drei- oder Split-Phase-Fähigkeit wird nicht zugesagt. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 | | TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 | | TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 | Kommunikation: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional Temperatur: Betrieb −20 bis 60 °C ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Betrieb −20 bis 60 °C GEHÄUSE Nicht angegeben 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Die bereitgestellte Broschüre enthält auf Druckseiten 15-16 zwei beschriftete Anschluss-/Schutzschalterdetails sowie Gehäuse- und Zellansichten. Ausschnitte vermeiden sichtbare Produktlogos ohne KI-Bearbeitung, Übermalung oder erfundene Konstruktion. Nicht eindeutig der Druckseite zuordenbare eingebettete Ansichten wurden ausgeschlossen. Die Ansichten belegen keine Pinbelegung, Kabelgrößen, Inbetriebnahmeschritte oder Installationskompatibilität. [![Originale Anschlussbeschriftungen](https://de.elvorka.com/assets/product-details/ta-terminal-map.png)](https://de.elvorka.com/assets/product-details/ta-terminal-map.png) Originale Anschlussbeschriftungen Anschlussfeld mit Beschriftungen für Last, Netz, optionalen Generator, PV und Kommunikation. [![Nahaufnahme des Anschlussfelds](https://de.elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://de.elvorka.com/assets/product-details/ta-terminal-closeup.png) Nahaufnahme des Anschlussfelds Nahaufnahme des Gehäuse-Anschlussfelds. [![Originale Schutzschalterbeschriftungen](https://de.elvorka.com/assets/product-details/ta-breaker-map.png)](https://de.elvorka.com/assets/product-details/ta-breaker-map.png) Originale Schutzschalterbeschriftungen Batterie-, PV1-, PV2-, Last- und Netzschutzschalter im gezeigten Fach. [![Nahaufnahme des Schutzschalterfachs](https://de.elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://de.elvorka.com/assets/product-details/ta-breaker-closeup.png) Nahaufnahme des Schutzschalterfachs Schutzschalter im Schutzschalterfach des Gehäuses. [![Oberer Gehäusebereich und Servicefach](https://de.elvorka.com/assets/product-details/ta-service-bay.png)](https://de.elvorka.com/assets/product-details/ta-service-bay.png) Oberer Gehäusebereich und Servicefach Oberes Gehäusefach mit Wechselrichter und Anschlussbereich. [![Detail der Zellanordnung](https://de.elvorka.com/assets/product-details/ta-cell-assembly.png)](https://de.elvorka.com/assets/product-details/ta-cell-assembly.png) Detail der Zellanordnung Oberseiten der Batteriezellen in einer teilweisen Innenansicht. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse Lastausgang In der Broschüre als Load Output bezeichnete Ausgangsposition. Netzeingang Als Grid Input bezeichnete Anschlussposition. Generatoreingang (optional) Der Generatoreingang ist in der Originalbeschriftung ausdrücklich optional. PV-Eingang Durch die Originalbeschriftung gekennzeichneter PV-Anschlussbereich. PV1-Eingangsschutzschalter Für PV1 Input bezeichneter Schutzschalter. PV2-Eingangsschutzschalter Für PV2 Input bezeichneter Schutzschalter. #### Kommunikation Kommunikationsport Als Communication Port bezeichneter Anschlussbereich. In dieser Bauteilansicht werden keine Protokoll-Pinbelegungen angegeben. #### Bedienelemente & Anzeigen Batterieschutzschalter Für den Batteriebereich bezeichneter Schutzschalter. Lastschutzschalter Für den Lastanschluss bezeichneter Schutzschalter. Netzschutzschalter Für den Netzanschluss bezeichneter Schutzschalter. Quelle: Residential ESS-Broschüre · PDF-Seite 8 · Druckseiten 15-16 --- https://de.elvorka.com/de/products/ta6000/ ELVORKA · eric@elvorka.com --- # TR standard. ![TR standard](https://de.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp) Niedervoltbatterie # TR standard. Fünf spezifizierte Kapazitäten als LFP-Wandbatterie. Kapazität, Gehäuse und einen kompatiblen externen Wechselrichter für die Installation auswählen. WECHSELRICHTER Kompatibler externer Wechselrichter erforderlich GEHÄUSE IP20; IP54 optional NENNENERGIE 5.12–20.07 kWh BATTERIESPANNUNG 51.2 V DC-Nennspannung [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | DC-Nennspannung (V) | | --- | --- | --- | | TR4000WX | 5.12 | 51.2 | | TR6000WX | 10.24 | 51.2 | | TR8000WX | 14.336 | 51.2 | | TR8500WX | 16.076 | 51.2 | | TR10000WX | 20.07 | 51.2 | Selbstheizung ist optional. Lade-/Entladestrom, Ausgangsleistung und Gehäuseoption für das genaue Modell und den Wechselrichter bestätigen. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 | | TR6000WX | 600 × 750 × 160 / W × H × D | 95 | | TR8000WX | 480 × 822 × 245 / W × H × D | 110 | | TR8500WX | 480 × 822 × 245 / W × H × D | 115 | | TR10000WX | 500 × 922 × 265 / W × H × D | 145 | Kommunikation: RS485 / RS232 / CAN; Wi-Fi / Bluetooth Temperatur: Laden 0 bis 55 °C ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Laden 0 bis 55 °C GEHÄUSE IP20; IP54 optional 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Fünf Modellnamen bilden den Familienkontext; das kompakte beschriftete Gehäuse ist keinem bestimmten Modell zugeordnet. Die Rollenbeschriftung nennt ausdrücklich TR8000WX und TR8500WX. Die Originalfotodetails sind begrenzt; Oberflächen oder Anschlüsse wurden nicht künstlich ergänzt. [![Vordere Bedienelemente und seitliche Anschlüsse](https://de.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://de.elvorka.com/assets/product-details/tr-standard-controls-annotated.png) Vordere Bedienelemente und seitliche Anschlüsse Touchscreen, Statusanzeigen, Kommunikationsports und DC-Klemmen am gezeigten Gehäuse. [![Hintere Halterung und Anschlussbeschriftungen](https://de.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://de.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png) Hintere Halterung und Anschlussbeschriftungen Hintere Montagehalterung und seitlicher Anschlussbereich der gezeigten Batterie. [![Detail des Stromkreisschalters](https://de.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://de.elvorka.com/assets/product-details/tr-standard-switch-closeup.png) Detail des Stromkreisschalters Stromkreisschalter mit ON/OFF-Markierungen. [![Originale hintere Dreiviertelansicht](https://de.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://de.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png) Originale hintere Dreiviertelansicht Hintere Dreiviertelansicht mit Montagehalterung und Anschlussseite. [![Originales Seitenprofil](https://de.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://de.elvorka.com/assets/product-details/tr-standard-side-profile.png) Originales Seitenprofil Seitenprofil mit Kommunikationsports und eingelassenem Griff. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse Batterie-Minuspol Negativer DC-Batterieleistungsanschluss gemäß Originalpfeil. Batterie-Pluspol Positiver DC-Batterieleistungsanschluss gemäß Originalpfeil. #### Kommunikation Wi-Fi / Bluetooth In der Beschriftung genannte Wi-Fi/Bluetooth-Funktion; App oder Kopplungsablauf werden hier nicht festgelegt. Potentialfreier Kontakt Bezeichnete Dry-Contact-Schnittstelle; Kontaktlogik, Pinbelegung und elektrische Werte fehlen. RS232 / CAN / RS485 In der Quelle genannte Kommunikationsschnittstellen; Protokollkompatibilität und Verdrahtung sind separat zu bestätigen. COM0 / COM1 Als COM0/COM1 bezeichnete Anschlüsse. Funktion, Pinbelegung und Grenzen des Parallelbetriebs stehen nicht auf dieser Seite. #### Bedienelemente & Anzeigen Touchscreen In der Originalbeschriftung bezeichneter Touchscreen. Betriebsstatusanzeige Betriebsanzeige; die Quelle schreibt Runing Status. Die Anzeigelogik wird nicht angegeben. Alarmanzeige In der Quelle bezeichnete Alarmanzeige. SOC-Anzeige In der Quelle bezeichnete SOC-Anzeige; Anzeigeschwellen sind nicht angegeben. Reset-Bedienelement Von der Quelle bezeichnetes Reset-Bedienelement; diese Seite enthält keine Bedienungsanweisung. Batterieschalter In der Quelle bezeichneter Batterieschalter; in dieser Beschriftung wird kein Schaltwert angegeben. #### Aufbau & Montage Klappgriff Mechanischer Klappgriff; kein elektrischer Anschluss. Wandhalterung In der Quelle bezeichnete Wandhalterung; Traglast und Befestigungsdetails fehlen hier. Rollen Rollen; die Originalbeschriftung nennt ausdrücklich TR8000WX und TR8500WX. Keine elektrische Schnittstelle. Quelle: Residential ESS-Broschüre · PDF-Seite 3 · Druckseiten 5-6 --- https://de.elvorka.com/de/products/tr-standard/ ELVORKA · eric@elvorka.com --- # HP K. ![HP K](https://de.elvorka.com/assets/optimized/06e5e5950abd6ed8-1405-q92.webp) Hochvoltbatterie # HP K. Vier bis acht LFP-Batteriemodule in fünf spezifizierten Stapelkonfigurationen. Die gewählte Spannung und Kommunikation mit einem kompatiblen externen Wechselrichter abstimmen. WECHSELRICHTER Kompatibler externer Wechselrichter erforderlich GEHÄUSE IP20; IP54 optional NENNENERGIE 20.48–40.96 kWh BATTERIESPANNUNG 204.8–409.6 V DC-Nennspannung [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | DC-Nennleistung (kW) | | --- | --- | --- | | HP2000K | 20.48 | 20 | | HP2500K | 25.6 | 25 | | HP3000K | 30.72 | 30 | | HP3500K | 35.84 | 35 | | HP4000K | 40.96 | 40 | Batterieseitige DC-Werte sind keine AC-Ausgangswerte des Wechselrichters. Das DC-Spannungsfenster des Wechselrichters für die gewählte Modulanzahl bestätigen. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | HP2000K | 580 × 390 × 918 / L × W × H | 213 | | HP2500K | 580 × 390 × 1089 / L × W × H | 259.5 | | HP3000K | 580 × 390 × 1260 / L × W × H | 306 | | HP3500K | 580 × 390 × 1431 / L × W × H | 352.5 | | HP4000K | 580 × 390 × 1602 / L × W × H | 399 | Kommunikation: RS485 / CAN; Wi-Fi / Bluetooth optional Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 60 °C ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 60 °C GEHÄUSE IP20; IP54 optional 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Die originale Front-/Farbdisplaygrafik zeigt vier 5.12kWh-Bereiche; die Familientabelle umfasst vier bis acht Module. Die Anschluss-/Bedienseite wird nicht ausdrücklich als Rückseite bezeichnet. Für diese Familie stehen keine separaten Bezeichnungen GND, parallele COM1/COM2, INV CAN/RS485 oder BMS-Debugging in der Quelle; daher werden sie nicht von HP Ultra übernommen. Pinbelegung und Installations-/Aktivierungsfolge fehlen. [![Anschluss-/Bedienseite – Originalbeschriftungen](https://de.elvorka.com/assets/product-details/hp-k-interface-callouts.png)](https://de.elvorka.com/assets/product-details/hp-k-interface-callouts.png) Anschluss-/Bedienseite – Originalbeschriftungen COM1 Reserve, COM2-Wechselrichteranschluss, DC24V/AC230V-Aktivierung und Steuerschalter. [![Farbdisplay-Seite](https://de.elvorka.com/assets/product-details/hp-k-front-screen-face.png)](https://de.elvorka.com/assets/product-details/hp-k-front-screen-face.png) Farbdisplay-Seite Vorderansicht der Farbdisplayeinheit und gestapelten Batteriemodule. [![Detail der PDU-Anschlüsse und Bedienelemente](https://de.elvorka.com/assets/product-details/hp-k-pdu-interface-detail.png)](https://de.elvorka.com/assets/product-details/hp-k-pdu-interface-detail.png) Detail der PDU-Anschlüsse und Bedienelemente Oberes Bedienfeld mit Anschlüssen, Anzeigen und Schaltern. [![Detail der oberen Einheit mit Farbdisplay](https://de.elvorka.com/assets/product-details/hp-k-color-screen-detail.png)](https://de.elvorka.com/assets/product-details/hp-k-color-screen-detail.png) Detail der oberen Einheit mit Farbdisplay Farbdisplaybereich an der Vorderseite der oberen Einheit. [![Detail des getrennten Modulstapels](https://de.elvorka.com/assets/product-details/hp-k-separated-modules-detail.png)](https://de.elvorka.com/assets/product-details/hp-k-separated-modules-detail.png) Detail des getrennten Modulstapels Getrennte Batteriemodule mit sichtbaren Kontaktflächen. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse Minuspol Minusanschluss gemäß ursprünglicher Bezugslinie. Pluspol Plusanschluss gemäß ursprünglicher Bezugslinie. Batterieaktivierung (DC24V) Separat als DC24V-Batterieaktivierung bezeichneter Punkt in der originalen Anschlussansicht. Batterieaktivierung (AC230V) Separat als AC230V-Batterieaktivierung bezeichneter Punkt in der originalen Anschlussansicht. #### Kommunikation COM1: Reserve COM1 ist ausdrücklich als Reserve bezeichnet. COM2: Anschluss zum Wechselrichter Die Quelle ordnet den Wechselrichteranschluss ausdrücklich COM2 zu. #### Bedienelemente & Anzeigen Farbdisplay Auf der gegenüberliegenden geschlossenen oberen Vorderseite bezeichnetes Display. Air Switch (Quellenbezeichnung) Auf der Anschluss-/Bedienseite als Air Switch bezeichneter Schalter/Schutzschalter. AC-Schalter Separates, als AC Switch bezeichnetes Bedienelement. Alarmanzeigen Durch die ursprüngliche Bezugslinie gekennzeichnete Alarmanzeigegruppe. Betriebsanzeigen Durch die ursprüngliche Bezugslinie gekennzeichnete Betriebsanzeigegruppe. Einstellbare Statusanzeige Merkmalsbeschriftung der separaten Eckansicht des Statuslichtstreifens auf Druckseite 11. #### Aufbau & Montage PDU Die obere Einheit über den Batteriebereichen wird als PDU bezeichnet; die Quelle erläutert die Abkürzung nicht. 5.12kWh Vier wiederholte 5.12kWh-Bereiche sind in der Einführungsgrafik bezeichnet. Untergestell Untergestell unterhalb des Batteriestapels. Quelle: Residential ESS-Broschüre · PDF-Seite 6 · Druckseiten 11-12 --- https://de.elvorka.com/de/products/hp-k/ ELVORKA · eric@elvorka.com --- # TB rack. ![TB rack](https://de.elvorka.com/assets/optimized/2b8fe35077745c40-1584-q92.webp) Niedervoltbatterie # TB rack. Vier spezifizierte LFP-Batteriekapazitäten für die Rackmontage und einen kompatiblen externen Wechselrichter. WECHSELRICHTER Kompatibler externer Wechselrichter erforderlich GEHÄUSE IP20 NENNENERGIE 5.12–16.076 kWh BATTERIESPANNUNG 51.2 V DC-Nennspannung [Projekt planen ↗](https://de.elvorka.com/de/#enquiry) ## Spezifikationen | Modell / Konfiguration | Energie (kWh) | DC-Nennleistung (kW) | | --- | --- | --- | | TB4000X | 5.12 | 5 | | TB6000X | 10.24 | 10 | | TB8000X | 14.336 | 10 | | TB8500X | 16.076 | 10 | Wi-Fi / Bluetooth ist für TB6000X, TB8000X und TB8500X aufgeführt, nicht für TB4000X. Leistungsangaben gelten batterieseitig für DC. | Modell | Abmessungen (mm) | Ca. kg | | --- | --- | --- | | TB4000X | 482 × 178 × 420 / W × H × D | 42 | | TB6000X | 482 × 223 × 550 / W × H × D | 78 | | TB8000X | 482 × 223 × 710 / W × H × D | 109.5 | | TB8500X | 482 × 223 × 710 / W × H × D | 112 | Kommunikation: RS485 / CAN / RS232 Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 60 °C ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. Temperatur: Laden 0 bis 55 °C; Entladen −20 bis 60 °C GEHÄUSE IP20 01 ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? 02 ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? 03 ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? Spezifikationen - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. PRODUKTDETAIL / ORIGINALUNTERLAGEN ## Jede Seite. Jeder Anschluss. Die originale Frontansicht und die beschriftete Explosionsansicht unterscheiden sich sichtbar; eine identische Hardwareversion ist nicht belegt. Quellenidentität jeder Ansicht beibehalten. Ein externes Rückseitenfoto fehlt. Interne/Thermikgrafiken nicht als äußere Rückseiten- oder Unterseitenfotos bezeichnen. [![Originale vordere Anschluss- und Bedienleiste](https://de.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://de.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png) Originale vordere Anschluss- und Bedienleiste Vordere Anschluss- und Bedienleiste, mit Minuspol links und Pluspol rechts. [![Minus-Leistungsanschluss, vorne links](https://de.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://de.elvorka.com/assets/product-details/tb-rack-negative-terminal.png) Minus-Leistungsanschluss, vorne links Minusanschluss und Minuszeichen vorne links. [![Plus-Leistungsanschluss, vorne rechts](https://de.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://de.elvorka.com/assets/product-details/tb-rack-positive-terminal.png) Plus-Leistungsanschluss, vorne rechts Plusanschluss und Pluszeichen vorne rechts. [![Originaler Kommunikations- und Bedienbereich](https://de.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://de.elvorka.com/assets/product-details/tb-rack-communication-controls.png) Originaler Kommunikations- und Bedienbereich Kommunikationsanschlüsse, Anzeigen und Ein-/Ausschalter auf der vorderen Bedienleiste. [![Originales Zell- und BMS-Konstruktionsdetail](https://de.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://de.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png) Originales Zell- und BMS-Konstruktionsdetail Teilweise Innenansicht mit Batteriezellen und BMS-Platine. ### Ihre Schnittstellen verstehen. #### Leistungsanschlüsse Plus-Leistungsanschluss Leistungsanschluss rechts aus Betrachtersicht am gezeigten Frontpanel, mit Original-Pluszeichen. Minus-Leistungsanschluss Leistungsanschluss links aus Betrachtersicht am gezeigten Frontpanel, mit Original-Minuszeichen. #### Kommunikation Dry Connect (Quellenbezeichnung) Die Quelle bezeichnet dies als Kommunikationsport Dry Connect. Kontaktlogik, Pinbelegung und elektrische Werte fehlen. COM0 / COM1 Parallelanschlüsse In dieser Quelle ausdrücklich als Parallel Port bezeichnete Anschlüsse. Grenzen des Parallelbetriebs und Verdrahtung fehlen. CAN / RS485 Als CAN/RS485 bezeichnete Kommunikationsportgruppe. Das Aussehen allein belegt weder Ethernet-Vernetzung noch ein kompatibles Wechselrichterprotokoll. RS232 Als RS232 bezeichneter Kommunikationsport; genaue Pinbelegung und benötigte Adapter werden nicht angegeben. #### Bedienelemente & Anzeigen Ein-/Ausschalter Ein-/Ausschalter laut Originalbeschriftung. Die Bedienungsfolge wird nicht angegeben. SOC / ALM / RUN-Anzeigen In der Quelle bezeichnete Anzeigegruppe. Einzelne Farbbedeutungen und Diagnosecodes sind nicht angegeben. Adressidentifikations-Steuerung Als Add bezeichnetes Bedienelement; laut Beschreibung automatische Adresserkennung. Einstellverfahren und Adresslogik fehlen. #### Aufbau & Montage Laserschweißen Die Broschüre beschreibt Laserschweißen der Aluminiumplatten-/Zellverbindung. Internes Konstruktionsmerkmal, kein Anschluss. Stahlhalterung Interne Stahlhalterung zur Zellfixierung; kein externer Anschluss. Kunststoff-Stahlband (Quellenwortlaut) Laut Quelle verhindert das Zellhalteband bewegungsbedingte Stöße; die Materialleistung wurde nicht unabhängig geprüft. Integriertes intelligentes BMS Integriertes BMS. Der Hersteller nennt Temperaturschutz, Kurzschlussschutz und Balancing; diese Auswertung überprüft die Funktionen nicht unabhängig. Tragegriff Stahlgriff laut Quellenbeschreibung. Kein elektrischer Anschluss. Quelle: Residential ESS-Broschüre · PDF-Seite 7 · Druckseiten 13-14 --- https://de.elvorka.com/de/products/tb-rack/ ELVORKA · eric@elvorka.com --- # Home storage. Clearly planned . HOME ENERGY STORAGE / GERMANY # Home storage. Clearly planned . Integrated systems and LFP batteries for a carefully specified home installation. Compare the battery, inverter relationship and connection details before choosing your configuration. [Explore the collection](https://de.elvorka.com/en/#products)[Find your fit](https://de.elvorka.com/en/#planner) One home. A considered system. Integrated storage or a battery for your inverter. ![EU 230 V — INSTALLATION ILLUSTRATION](https://de.elvorka.com/assets/optimized/1a28066966a58cf7-1536-q92.webp) INSTALLATION ILLUSTRATION 01 / 03 INSTALLATION ILLUSTRATION [INVERTER INCLUDED EU 230 V Integrated battery + inverter](https://de.elvorka.com/en/#products) SMALLER FOOTPRINT. GREATER POSSIBILITIES. 07 Product families 29 Listed configurations 5.12–48 kWh Nominal energy across the collection [Product tour](https://de.elvorka.com/en/#product-tour) Product tour ## One home. A considered system. Integrated storage or a battery for your inverter. RESIDENTIAL ENERGY STORAGE / GERMANY LFP ![Installation illustration of a TR Pro battery in a residential equipment area.](https://de.elvorka.com/assets/optimized/20e2f83648685da5-1536-q92.webp) HOME BATTERY INSTALLATION Product scene illustration [TR PRO / WALL STORAGE ![elvorka TR Pro wall-mounted LFP battery](https://de.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp) Storage. In its element. 10.24 / 16.076 kWh nominal energy 51.2 V NOMINAL DC IP66 ENCLOSURE](https://de.elvorka.com/en/#products) [All products](https://de.elvorka.com/en/#products) 01 TWO WAYS TO STORE ## Start with your setup. A new installation or an existing inverter. Choose your starting point. [INTEGRATED SYSTEMS ### A fresh start. All in one. Battery and inverter in one system. A coordinated starting point for a new installation. EXPLORE ALL-IN-ONE 6 listed configurations](https://de.elvorka.com/en/#products) [BATTERY SYSTEMS ### Your inverter. More possibility. Wall, stack or rack-mounted LFP storage. Match the voltage and confirm compatibility. EXPLORE BATTERIES 23 listed configurations](https://de.elvorka.com/en/#products) TR PRO / MATERIAL & FORM 01 — ENCLOSURE / FRONT ELEVATION PRODUCT DETAIL 03 LOOK A LITTLE CLOSER ## Details you can build around. Start with the chemistry. Check the voltage. Specify the enclosure. Every good installation begins with a clear understanding of the product. LiFePO₄ LFP battery chemistry 51.2 V TR Pro nominal DC voltage IP66 TR Pro enclosure rating CAN / RS485 Communication interfaces [See TR Pro specifications](https://de.elvorka.com/en/#products) ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. 02 THE COLLECTION ## Storage. Clearly specified. Seven families. Three installation formats. Compare the details that matter. 3 product families ### TR Pro. Wall-mounted. Thoughtfully contained. 10.24 / 16.076 kWh LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter. [Explore all product details ↗](https://de.elvorka.com/en/products/tr-pro/) ### EU 230 V. An integrated starting point. 10.24 / 16.076 kWh An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW. [Explore all product details ↗](https://de.elvorka.com/en/products/eu-230v/) ### HP Ultra. Storage with room to grow. 8–48 kWh A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter. [Explore all product details ↗](https://de.elvorka.com/en/products/hp-ultra/) Confirm the selected configuration, inverter compatibility, project requirements and supply arrangements before ordering. Your setup matters. Battery-only products require a compatible external inverter. [Download the full collection](https://de.elvorka.com/downloads/ELVORKA_de_en_Product_Guide.pdf) PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Look beyond the headline specifications. Explore original product views, labelled interfaces and details for each family. 05 KNOW YOUR ESSENTIALS ## Explore your backup. Start with the essentials you want to keep running. Adjust the load and battery size to explore an indicative backup duration. Battery energy is measured in kWh . Appliance power is measured in kW . Your inverter must support the load. Inverter included in all-in-one systems; external for battery-only products. BACKUP EXPLORER YOUR ESTIMATE Watt / kW Battery capacity 10.24 kWh Average essential load 1.0 kW 0.2 kW 5.0 kW These are planning examples, not measured usage or guaranteed runtime. Confirm starting current, backup-capable circuits and the selected inverter's AC output. INDICATIVE BACKUP 8.3 hours How this estimate works Nominal battery capacity × 90% assumed usable depth × 90% assumed inverter efficiency ÷ average load. These are planning assumptions, not guaranteed product ratings. Actual backup varies with usable energy, temperature, battery age, standby use and load changes. Starting currents and inverter limits must be checked separately. [Use this in my project](https://de.elvorka.com/en/#enquiry) OUR PRODUCTS / AT HOME ### A clearer plan for your home storage. For homeowners and installation professionals planning projects in Germany: start with the existing system, the space available and the loads you want to support. These are planning scenarios, not completed local customer references. EU 230 V / INVERTER INCLUDED #### Plan a new integrated system. Compare all-in-one storage with its inverter already integrated. Specify the required AC configuration and have the installation design checked for the project. HP ULTRA / BATTERY ONLY #### Match an existing inverter. Compare the 51.2 V and high-voltage battery families against your inverter's DC window, supported communication and operating settings. Battery-only products need a compatible external inverter. TR PRO / BATTERY ONLY #### Define your essential loads. List the selected lighting, refrigeration and connectivity loads. Use the Watt explorer for an indicative runtime, then confirm backup operation, circuits and protection with the installation professional. Installation illustrations featuring products from this collection. Scenes are composites, not photographs of completed customer projects. Visible layouts are illustrative; final connections, protection and clearances follow the selected model’s installation manual and site design. 06 KNOW YOUR SYSTEM ## Choose with clarity. [elvorka product collection English · PDF · 8 pages PDF](https://de.elvorka.com/downloads/ELVORKA_de_en_Product_Guide.pdf) [elvorka views & interfaces 35 source views · 7 families · English PDF PDF](https://de.elvorka.com/downloads/product-views-and-interfaces.pdf)[Explore the detail library Original product views, labelled interfaces and source references.](https://de.elvorka.com/en/#technical-library) [Original product collection · English PDF ↘](https://de.elvorka.com/downloads/energy-product-collection.pdf) Good questions. Straight answers. Start with the system you have. Choose the storage you need. What needs to be confirmed for a home storage project in Germany? Confirm the exact product configuration, AC supply and phase requirements, battery voltage range, inverter communication, essential-load circuits and installation location. Country-specific suitability and any required documentation must be checked for the selected equipment and project; this catalogue is not an approval certificate. Can I connect a 51.2 V battery to my existing inverter? A nominal voltage match alone does not confirm compatibility. Your installer should verify the inverter’s DC voltage window, charge and discharge current, CAN or RS485 protocol, firmware and protection settings. High-voltage batteries must not be connected to a low-voltage inverter. What should be checked for a project in Germany? Confirm the installation’s AC supply, inverter phase requirements, essential-load circuits and local electrical requirements. The EU integrated range lists 230 V AC and 50 / 60 Hz. TA6000 lists 120 V US and 230 V EU options; specify the required market configuration. The project’s backup circuits and protection requirements need installer review. Can these batteries be installed outdoors? TR Pro and HP Ultra list IP66 enclosures. Other families have different or optional protection ratings. An IP rating alone is not an installation instruction: check the selected model’s temperature limits, clearances, shelter, ventilation and installer requirements. Does more battery capacity mean more output power? No. Capacity in kWh describes stored energy. Power in kW describes the rate energy can be delivered. Battery-side DC ratings and inverter AC output are different. Both the selected battery configuration and inverter must support your operating and starting loads. How do I confirm price, warranty and availability? Prepare a project brief with your city, required loads, existing inverter and selected product. Ask your supplier to confirm the exact configuration, quotation currency, warranty terms, installation scope, delivery timing and after-sales arrangements in writing. Can the battery go in an unheated garage? Only after checking the actual temperature, damp and exposure against the exact model's instructions. Several families list charging from 0 °C. Confirm any heating configuration and charge protection; colder discharge limits are not charging permission. Can I back up a heat pump or electric cooker? Assess those loads separately. Their running power and starting requirements can dominate the design; the example essential-load totals do not include them. Confirm both battery DC capability and inverter AC and backup-circuit capability. Does a 230 V product listing confirm suitability for my installation? No. Confirm the selected AC configuration, phase arrangement, required documentation, inverter compatibility and installation design for the actual project. The catalogue does not establish country-specific approval. Your next chapter ## Start with your setup. [01 ### Explore the collection Seven families. Three installation formats.](https://de.elvorka.com/en/#products)[02 ### Find your fit Start with the essentials you want to keep running.](https://de.elvorka.com/en/#planner)[03 ### Prepare my enquiry Tell the story of your home.](https://de.elvorka.com/en/#enquiry) YOUR NEXT CHAPTER ## Let’s plan your system . Tell the story of your home. Prepare a clear project brief to share with your installer or storage supplier. YOUR HOME. YOUR ENERGY. [eric@elvorka.com](mailto:eric@elvorka.com) Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. Your name (optional) Project city * Your email Phone / WhatsApp (optional, include country code) Company (optional) I am planning for Existing inverter Product interest What matters to you? Region and seasonal exposure Lowest / highest observed equipment-room temperature AC supply and required phase arrangement Your submitted details are saved for the ELVORKA team to review and follow up. Please avoid including passwords, identity documents or unrelated sensitive information. I agree that ELVORKA may use these details to respond to this project enquiry. ELVORKA ## A clearer view of home storage. Practical reading for choosing battery capacity, checking equipment-room conditions and preparing a useful installation brief. --- https://de.elvorka.com/en/ ELVORKA · eric@elvorka.com --- # TR Pro. ![TR Pro](https://de.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp) Low-voltage battery # TR Pro. LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP66 NOMINAL ENERGY 10.24 / 16.076 kWh BATTERY VOLTAGE 51.2 V nominal DC [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated DC (kW) | | --- | --- | --- | | TR6000WX-Pro | 10.24 | 10 | | TR8500WX-Pro | 16.076 | 10 | | TR8500WX-ProU | 16.076 | 10 | Self-heating is optional. Power ratings are battery-side DC; actual AC output depends on the selected inverter. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TR6000WX-Pro | 802 × 620 × 179 / H × L × D | 95 | | TR8500WX-Pro | 822 × 500 × 250 / H × L × D | 115.5 | | TR8500WX-ProU | 872 × 500 × 250 / H × L × D | 120 | Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ENCLOSURE IP66 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The panel illustrates one wheeled representative housing rather than proving every Pro SKU has the same lower body or port placement. Roller is a wheel. Main Circuit Breaker and Battery Switch are separate source labels. Full embedded switch-photo content beyond the printed crop is not promoted to new interface claims. [![Connection-side terminal labels](https://de.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)](https://de.elvorka.com/assets/product-details/tr-pro-terminal-labels.png) Connection-side terminal labels Battery terminals, switch, Wi-Fi antenna and communication ports on the cabinet side. [![Main breaker and folding handle](https://de.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)](https://de.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png) Main breaker and folding handle Main circuit breaker and folding handle on the illustrated cabinet side. [![Original connection-side three-quarter view](https://de.elvorka.com/assets/product-details/tr-pro-connection-side.png)](https://de.elvorka.com/assets/product-details/tr-pro-connection-side.png) Original connection-side three-quarter view Connection-side view of the cabinet, battery terminals and folding handle. [![Original narrow side profile](https://de.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)](https://de.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png) Original narrow side profile Narrow side profile of the illustrated cabinet. [![Original circuit-switch photograph](https://de.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)](https://de.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png) Original circuit-switch photograph Circuit-control switch with ON and OFF position markings. ### Know your interfaces. #### Power connections Positive battery terminal Positive DC battery terminal identified on the connection side. Negative battery terminal Negative DC battery terminal identified on the connection side. #### Communication RS485 RS485 interface named in the source; pinout and compatible device list are not provided. Wi-Fi antenna Wi-Fi antenna identified by the original arrow. CAN CAN communication interface named in the source; protocol version and pinout are not specified. RS232 RS232 communication interface named in the source; pinout is not specified. COM1 Port named COM1; this page does not explicitly define its role or wiring. COM0 Port named COM0; this page does not explicitly define its role or wiring. #### Controls & indicators Breathing light Front status-light strip identified as a breathing light. Colour meanings and operating logic are not specified. Main circuit breaker Main circuit breaker identified by the original arrow. Trip ratings and wiring are not provided here. Battery switch Battery switch separately named in the connection-side callout; do not merge this label with Main Circuit Breaker without a model-specific manual. #### Structure & mounting Wall-mounted bracket Mechanical wall-mounting bracket; not an electrical interface. Rollers Wheels shown on the representative housing. The label is mechanical and is not a connector or bottom communication port. Folding handle Mechanical folding handle; not an electrical connector. Source: Residential ESS brochure · PDF page 4 · printed pages 7-8 --- https://de.elvorka.com/en/products/tr-pro/ ELVORKA · eric@elvorka.com --- # EU 230 V. ![EU 230 V](https://de.elvorka.com/assets/optimized/ed4fde160f2f91fd-1048-q92.webp) Integrated system # EU 230 V. An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW. INVERTER Included ENCLOSURE IP21 NOMINAL ENERGY 10.24 / 16.076 kWh AC CONFIGURATION 230 V AC / 50 or 60 Hz [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated AC (kW) | | --- | --- | --- | | 6.2K-10/16KWH-EU | 10.24 | 6.2 | | 6.2K-10/16KWH-EU | 16.076 | 6.2 | | 12K-16KWH-EU | 16.076 | 12 | 6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 105 | | 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 | | 12K-16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 | Communication: USB / RS485 / dry contact Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C ENCLOSURE IP21 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail. [![Original numbered interface map](https://de.elvorka.com/assets/product-details/eu-interface-map.png)](https://de.elvorka.com/assets/product-details/eu-interface-map.png) Original numbered interface map Numbered map of the AC, battery, PV and communication connections. [![AC and battery connection side](https://de.elvorka.com/assets/product-details/eu-ac-side-full.png)](https://de.elvorka.com/assets/product-details/eu-ac-side-full.png) AC and battery connection side AC and battery connection side with cooling fans and the battery breaker. [![AC and battery upper detail](https://de.elvorka.com/assets/product-details/eu-ac-side-upper.png)](https://de.elvorka.com/assets/product-details/eu-ac-side-upper.png) AC and battery upper detail Upper AC connection area, cooling fans and BAT terminals. [![PV and communication side](https://de.elvorka.com/assets/product-details/eu-pv-side-full.png)](https://de.elvorka.com/assets/product-details/eu-pv-side-full.png) PV and communication side PV and communication side, including the battery communication ports. [![PV and communication upper detail](https://de.elvorka.com/assets/product-details/eu-pv-side-upper.png)](https://de.elvorka.com/assets/product-details/eu-pv-side-upper.png) PV and communication upper detail Ventilation grille above the PV and communication connection area. ### Know your interfaces. #### Power connections AC input / output The AC connection identified by number 1 in the original map. AC input breaker Breaker labelled for the AC input. BAT+ / BAT- Positive and negative battery terminals, as labelled in the source. PV input Input identified for the PV connection. #### Communication Parallel communication port Communication connection labelled for parallel operation; configuration availability must be confirmed separately. Dry contact control Control interface labelled as dry contact in the brochure. RS485 / BMS communication port The communication connection named RS485/BMS in the original label. Wi-Fi port Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation. USB communication port Communication interface labelled USB. Battery communication ports The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs. #### Controls & indicators Battery breaker Breaker identified for the battery section. Source: EU 230 V product sheet · PDF page 1 --- https://de.elvorka.com/en/products/eu-230v/ ELVORKA · eric@elvorka.com --- # HP Ultra. ![HP Ultra](https://de.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp) High-voltage battery # HP Ultra. A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP66 / aluminium alloy NOMINAL ENERGY 8–48 kWh BATTERY VOLTAGE Confirm selected configuration [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Max. DC (kW) | | --- | --- | --- | | HP Ultra-8.0 | 8 | 4 | | HP Ultra-16.0 | 16 | 8 | | HP Ultra-24.0 | 24 | 12 | | HP Ultra-32.0 | 32 | 16 | | HP Ultra-40.0 | 40 | 20 | | HP Ultra-48.0 | 48 | 24 | System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 | | HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 | | HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 | | HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 | | HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 | | HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 | Communication: CAN / RS485 / Wi-Fi / Bluetooth Temperature: Confirm selected configuration ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Confirm selected configuration ENCLOSURE IP66 / aluminium alloy 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models. [![DC electrical / heatsink face - original callouts](https://de.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://de.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png) DC electrical / heatsink face - original callouts DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate. [![Communication and parallel-interface face - original callouts](https://de.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://de.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png) Communication and parallel-interface face - original callouts Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND. [![Communication-side detail (partial oblique view)](https://de.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://de.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png) Communication-side detail (partial oblique view) Oblique detail of the stack's communication-side connector area. [![Module top / mating surfaces](https://de.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://de.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png) Module top / mating surfaces Battery module top and mating surfaces. ### Know your interfaces. #### Power connections Positive Pole Positive terminal identified by the original leader line on the electrical face. Negative Pole Negative terminal identified by the original leader line on the electrical face. #### Communication Bluetooth/WIFI Antenna Antenna label on the upper communication-side area. Backup Com The brochure labels this connection 'Backup Com' but does not explain its exact role. INV CAN/RS485 Com The INV-labelled CAN/RS485 communication connection shown in the original diagram. Parallel COM1 First parallel-communication label near the lower part of the illustrated interface face. Parallel COM2 Second parallel-communication label near the lower part of the illustrated interface face. #### Controls & indicators Switch Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified. DC Breaker DC breaker on the electrical / heatsink face. Breathing Light Light strip called out at the upper front portion in the oblique construction view. #### Structure & mounting Heat Dissipation Aluminum Plate Heat-dissipation aluminum plate called out on the slim electrical-side illustration. Wall Mounted Bracket Mounting brackets shown on the vent-side illustration. PDU PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation. Module Repeated battery sections below the top PDU. Base Base at the bottom of the illustrated stack. BMS Debugging Interface BMS debugging interface identified on the communication-side illustration. Pressure Relief Valve Pressure-relief component called out in the communication-side oblique view. GND Ground connection labelled GND at the bottom of the interface-side illustration. Source: Residential ESS brochure · PDF page 5 · printed pages 9-10 --- https://de.elvorka.com/en/products/hp-ultra/ ELVORKA · eric@elvorka.com --- # TA6000. ![TA6000](https://de.elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp) Integrated system # TA6000. Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration. INVERTER Included ENCLOSURE Not specified NOMINAL ENERGY 10.24–20.48 kWh AC CONFIGURATION 120 V US / 230 V EU AC options [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | AC options (kW) | | --- | --- | --- | | TA6000-M2 | 10.24 | 6–10 | | TA6000-M3 | 15.36 | 6–12 | | TA6000-M4 | 20.48 | 6–12 | Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 | | TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 | | TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 | Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional Temperature: Operating −20 to 60 °C ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Operating −20 to 60 °C ENCLOSURE Not specified 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility. [![Original terminal labels](https://de.elvorka.com/assets/product-details/ta-terminal-map.png)](https://de.elvorka.com/assets/product-details/ta-terminal-map.png) Original terminal labels Connection panel labelled for load, grid, optional generator, PV and communication. [![Terminal panel close-up](https://de.elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://de.elvorka.com/assets/product-details/ta-terminal-closeup.png) Terminal panel close-up Close-up of the cabinet terminal panel. [![Original breaker labels](https://de.elvorka.com/assets/product-details/ta-breaker-map.png)](https://de.elvorka.com/assets/product-details/ta-breaker-map.png) Original breaker labels Battery, PV1, PV2, load and grid breakers in the illustrated compartment. [![Breaker compartment close-up](https://de.elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://de.elvorka.com/assets/product-details/ta-breaker-closeup.png) Breaker compartment close-up Circuit breakers within the cabinet's breaker compartment. [![Upper cabinet and service bay](https://de.elvorka.com/assets/product-details/ta-service-bay.png)](https://de.elvorka.com/assets/product-details/ta-service-bay.png) Upper cabinet and service bay Upper cabinet compartment with the inverter and connection area. [![Cell assembly detail](https://de.elvorka.com/assets/product-details/ta-cell-assembly.png)](https://de.elvorka.com/assets/product-details/ta-cell-assembly.png) Cell assembly detail Battery cell tops in a partial internal illustration. ### Know your interfaces. #### Power connections Load Output Output position identified as Load Output in the brochure. Grid Input Connection position identified as Grid Input. Generator Input (optional) The generator input is explicitly marked optional in the original callout. PV Input PV connection area identified by the original callout. PV1 Input Breaker Breaker identified for PV1 Input. PV2 Input Breaker Breaker identified for PV2 Input. #### Communication Communication Port Connection area labelled Communication Port. No protocol pin assignments are specified in this component view. #### Controls & indicators Battery Breaker Breaker labelled for the battery section. Load Breaker Breaker identified for the load connection. Grid Breaker Breaker identified for the grid connection. Source: Residential ESS brochure · PDF page 8 · printed pages 15-16 --- https://de.elvorka.com/en/products/ta6000/ ELVORKA · eric@elvorka.com --- # TR standard. ![TR standard](https://de.elvorka.com/assets/optimized/54d556eb3b41e40a-1295-q92.webp) Low-voltage battery # TR standard. Five specified capacities in a wall-mounted LFP battery format. Select the capacity, enclosure and a compatible external inverter for the installation. INVERTER Compatible external inverter required ENCLOSURE IP20; IP54 optional NOMINAL ENERGY 5.12–20.07 kWh BATTERY VOLTAGE 51.2 V nominal DC [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Nominal DC (V) | | --- | --- | --- | | TR4000WX | 5.12 | 51.2 | | TR6000WX | 10.24 | 51.2 | | TR8000WX | 14.336 | 51.2 | | TR8500WX | 16.076 | 51.2 | | TR10000WX | 20.07 | 51.2 | Self-heating is optional. Confirm the charge/discharge current, output power and enclosure option for the exact model and inverter. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TR4000WX | 400 × 750 × 160 / W × H × D | 53.5 | | TR6000WX | 600 × 750 × 160 / W × H × D | 95 | | TR8000WX | 480 × 822 × 245 / W × H × D | 110 | | TR8500WX | 480 × 822 × 245 / W × H × D | 115 | | TR10000WX | 500 × 922 × 265 / W × H × D | 145 | Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth Temperature: Charge 0 to 55 °C ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Charge 0 to 55 °C ENCLOSURE IP20; IP54 optional 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. Five model names provide family context, but the compact callout housing is not individually assigned to a SKU. The roller annotation expressly names TR8000WX and TR8500WX. Native photo detail is limited; no replacement surface or port detail is synthesized. [![Front controls and side terminals](https://de.elvorka.com/assets/product-details/tr-standard-controls-annotated.png)](https://de.elvorka.com/assets/product-details/tr-standard-controls-annotated.png) Front controls and side terminals Touch screen, status indicators, communication ports and DC terminals on the illustrated cabinet. [![Rear bracket and terminal-side labels](https://de.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png)](https://de.elvorka.com/assets/product-details/tr-standard-rear-bracket-annotated.png) Rear bracket and terminal-side labels Rear mounting bracket and side terminal area of the illustrated battery. [![Circuit control switch detail](https://de.elvorka.com/assets/product-details/tr-standard-switch-closeup.png)](https://de.elvorka.com/assets/product-details/tr-standard-switch-closeup.png) Circuit control switch detail Circuit control switch with ON/OFF markings. [![Original rear three-quarter view](https://de.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png)](https://de.elvorka.com/assets/product-details/tr-standard-rear-threequarter.png) Original rear three-quarter view Rear three-quarter view showing the mounting bracket and terminal side. [![Original side profile](https://de.elvorka.com/assets/product-details/tr-standard-side-profile.png)](https://de.elvorka.com/assets/product-details/tr-standard-side-profile.png) Original side profile Side profile showing communication ports and the recessed handle. ### Know your interfaces. #### Power connections Negative battery terminal Negative DC battery power terminal as identified by the original arrow. Positive battery terminal Positive DC battery power terminal as identified by the original arrow. #### Communication Wi-Fi / Bluetooth Wi-Fi/Bluetooth feature identified in the callout; no app or pairing workflow is established here. Dry contact Dry-contact interface identified; contact logic, pinout and electrical ratings are not supplied. RS232 / CAN / RS485 Communications interfaces named in the source; protocol compatibility and wiring require separate confirmation. COM0 / COM1 Ports named COM0/COM1. This page does not state their role, pinout or parallel-system limits. #### Controls & indicators Touch screen Touch-screen display identified in the original callout. Running status indicator Running-status indication; source spelling is 'Runing Status'. Indicator logic is not specified. Alarm indicator Alarm indication identified in the source. SOC indicator SOC indicator identified in the source; display thresholds are not specified. Reset control Reset control identified by the source; operating procedure is not given on this page. Battery switch Battery switch identified in the source; no switching rating is given in this callout. #### Structure & mounting Folding handle Mechanical folding handle; not an electrical connector. Wall-mounted bracket Wall-mounting bracket identified in the source; mounting load and fixing details are not supplied here. Rollers Rollers; the original annotation explicitly names TR8000WX and TR8500WX. Not an electrical interface. Source: Residential ESS brochure · PDF page 3 · printed pages 5-6 --- https://de.elvorka.com/en/products/tr-standard/ ELVORKA · eric@elvorka.com --- # HP K. ![HP K](https://de.elvorka.com/assets/optimized/06e5e5950abd6ed8-1405-q92.webp) High-voltage battery # HP K. Four to eight LFP battery modules in five specified stacked configurations. Match the selected voltage and communication settings to a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP20; IP54 optional NOMINAL ENERGY 20.48–40.96 kWh BATTERY VOLTAGE 204.8–409.6 V nominal DC [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated DC (kW) | | --- | --- | --- | | HP2000K | 20.48 | 20 | | HP2500K | 25.6 | 25 | | HP3000K | 30.72 | 30 | | HP3500K | 35.84 | 35 | | HP4000K | 40.96 | 40 | Battery-side DC ratings are not inverter AC output ratings. Confirm the inverter DC voltage window for the chosen module count. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | HP2000K | 580 × 390 × 918 / L × W × H | 213 | | HP2500K | 580 × 390 × 1089 / L × W × H | 259.5 | | HP3000K | 580 × 390 × 1260 / L × W × H | 306 | | HP3500K | 580 × 390 × 1431 / L × W × H | 352.5 | | HP4000K | 580 × 390 × 1602 / L × W × H | 399 | Communication: RS485 / CAN; Wi-Fi / Bluetooth optional Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ENCLOSURE IP20; IP54 optional 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The original front/color-screen diagram shows four 5.12kWh sections; the family specification table spans four to eight modules. The connection/control face is not explicitly named rear. No separate GND, parallel COM1/COM2, INV CAN/RS485 or BMS debugging label is printed for this family, so none is imported from HP Ultra. The brochure supplies no pinout or installation/activation sequence. [![Connection/control face - original labels](https://de.elvorka.com/assets/product-details/hp-k-interface-callouts.png)](https://de.elvorka.com/assets/product-details/hp-k-interface-callouts.png) Connection/control face - original labels COM1 reserve, COM2 inverter connection, DC24V/AC230V activation and control switches. [![Color-screen face](https://de.elvorka.com/assets/product-details/hp-k-front-screen-face.png)](https://de.elvorka.com/assets/product-details/hp-k-front-screen-face.png) Color-screen face Front view of the color-screen unit and stacked battery modules. [![PDU connector and control detail](https://de.elvorka.com/assets/product-details/hp-k-pdu-interface-detail.png)](https://de.elvorka.com/assets/product-details/hp-k-pdu-interface-detail.png) PDU connector and control detail Top-unit panel with connectors, indicators and switches. [![Color-screen top-unit detail](https://de.elvorka.com/assets/product-details/hp-k-color-screen-detail.png)](https://de.elvorka.com/assets/product-details/hp-k-color-screen-detail.png) Color-screen top-unit detail Color-screen area on the front of the top unit. [![Separated module stack detail](https://de.elvorka.com/assets/product-details/hp-k-separated-modules-detail.png)](https://de.elvorka.com/assets/product-details/hp-k-separated-modules-detail.png) Separated module stack detail Separated battery modules showing their mating surfaces. ### Know your interfaces. #### Power connections Negative Pole Negative terminal as identified by the original leader line. Positive Pole Positive terminal as identified by the original leader line. Battery Activation (DC24V) A separately labelled DC24V battery-activation point in the original connection-face diagram. Battery Activation (AC230V) A separately labelled AC230V battery-activation point in the original connection-face diagram. #### Communication COM1: Reserve COM1 is explicitly labelled Reserve. COM2: Connect To Inverter The source explicitly assigns the inverter connection to COM2. #### Controls & indicators Color Screen Screen identified on the opposite, closed front-top face. Air Switch Switch/breaker labelled Air Switch on the connection/control face. AC Switch A separate control labelled AC Switch. Alarm Lights Alarm indicator group identified by the original leader line. Running Lights Running indicator group identified by the original leader line. Adjustable Status Indicator Feature caption on the separate status-line corner illustration on printed page 11. #### Structure & mounting PDU The top unit identified as PDU above the battery sections; the source does not expand the abbreviation. 5.12kWh Four repeated 5.12kWh sections are called out in the introduction diagram. Chassis Bottom chassis called out below the battery stack. Source: Residential ESS brochure · PDF page 6 · printed pages 11-12 --- https://de.elvorka.com/en/products/hp-k/ ELVORKA · eric@elvorka.com --- # TB rack. ![TB rack](https://de.elvorka.com/assets/optimized/2b8fe35077745c40-1584-q92.webp) Low-voltage battery # TB rack. Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter. INVERTER Compatible external inverter required ENCLOSURE IP20 NOMINAL ENERGY 5.12–16.076 kWh BATTERY VOLTAGE 51.2 V nominal DC [Start your project ↗](https://de.elvorka.com/en/#enquiry) ## Specifications | Model / configuration | Energy (kWh) | Rated DC (kW) | | --- | --- | --- | | TB4000X | 5.12 | 5 | | TB6000X | 10.24 | 10 | | TB8000X | 14.336 | 10 | | TB8500X | 16.076 | 10 | Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC. | Model | Dimensions (mm) | Approx. kg | | --- | --- | --- | | TB4000X | 482 × 178 × 420 / W × H × D | 42 | | TB6000X | 482 × 223 × 550 / W × H × D | 78 | | TB8000X | 482 × 223 × 710 / W × H × D | 109.5 | | TB8500X | 482 × 223 × 710 / W × H × D | 112 | Communication: RS485 / CAN / RS232 Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C ENCLOSURE IP20 01 ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? 02 ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? 03 ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? Specifications - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. PRODUCT DETAIL / ORIGINAL LITERATURE ## Every side. Every connection. The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos. [![Original front terminal and control strip](https://de.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://de.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png) Original front terminal and control strip Front terminal and control strip, with the negative terminal left and positive terminal right. [![Negative power terminal, front left](https://de.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://de.elvorka.com/assets/product-details/tb-rack-negative-terminal.png) Negative power terminal, front left Negative terminal and minus mark at the front left. [![Positive power terminal, front right](https://de.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://de.elvorka.com/assets/product-details/tb-rack-positive-terminal.png) Positive power terminal, front right Positive terminal and plus mark at the front right. [![Original communication and control area](https://de.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://de.elvorka.com/assets/product-details/tb-rack-communication-controls.png) Original communication and control area Communication connectors, indicators and power switch on the front control strip. [![Original cell and BMS construction detail](https://de.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://de.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png) Original cell and BMS construction detail Partial internal illustration showing battery cells and the BMS board. ### Know your interfaces. #### Power connections Positive power terminal Power port on the viewer's right in the illustrated front panel, with the original plus mark. Negative power terminal Power port on the viewer's left in the illustrated front panel, with the original minus mark. #### Communication Dry Connect (source label) Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given. COM0 / COM1 parallel ports Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied. CAN / RS485 Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol. RS232 Communication port named RS232; exact pinout and adapter requirements are not provided. #### Controls & indicators Power switch Power on/off switch as described in the original caption. Operating sequence is not supplied. SOC / ALM / RUN indicators Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified. Address identification control Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified. #### Structure & mounting Laser welding The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port. Steel holder Internal steel holder identified as fixing the cells; not an external connector. Plastic steel belt (source wording) Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated. Built-in smart BMS Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions. Portable handle Steel handle as described in the source. It is not an electrical port. Source: Residential ESS brochure · PDF page 7 · printed pages 13-14 --- https://de.elvorka.com/en/products/tb-rack/ ELVORKA · eric@elvorka.com --- # Heimspeicher besser verstehen. Journal / Deutschland # Heimspeicher besser verstehen. Praxisnahe Beiträge zur Speicherkapazität, zu den Bedingungen im Technikraum und zu einer aussagekräftigen Projektanfrage. Journal ## [Wie viel Batteriespeicher braucht Ihr Zuhause?](https://de.elvorka.com/de/blog/battery-capacity/) Beginnen Sie mit den gewünschten Ersatzstromkreisen. Gespeicherte Energie, Betriebsleistung und Anlaufbedarf sind getrennte Größen. [Artikel lesen](https://de.elvorka.com/de/blog/battery-capacity/) Journal ## [Den Batterieplatz vor der Installation auswählen.](https://de.elvorka.com/de/blog/installation-environment/) Raumtemperatur, Feuchte, Zugang und Systemaufbau zählen mehr als ein landesweiter Klimamittelwert. [Artikel lesen](https://de.elvorka.com/de/blog/installation-environment/) ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) --- https://de.elvorka.com/de/blog/ ELVORKA · eric@elvorka.com --- # Einblicke in die ELVORKA Produktwelt. Neuigkeiten / Deutschland # Einblicke in die ELVORKA Produktwelt. Neue Produktunterlagen und Website-Inhalte. Dokumentierte Angaben und projektspezifische Anforderungen bleiben klar erkennbar. Neuigkeiten ## [Die internationale ELVORKA Produktübersicht ist online.](https://de.elvorka.com/de/news/product-collection/) Sieben Produktfamilien, 29 aufgeführte Konfigurationen und sprachbezogene Produktunterlagen sind in den Länderausgaben verknüpft. [Artikel lesen](https://de.elvorka.com/de/news/product-collection/) Neuigkeiten ## [Originalansichten und Anschlussinformationen leichter finden.](https://de.elvorka.com/de/news/technical-library/) 35 Quellabbildungen und 97 beschriftete Merkmale verbinden Produktseiten mit der technischen Bibliothek. [Artikel lesen](https://de.elvorka.com/de/news/technical-library/) ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) --- https://de.elvorka.com/de/news/ ELVORKA · eric@elvorka.com --- # Wie viel Batteriespeicher braucht Ihr Zuhause? Journal / Deutschland # Wie viel Batteriespeicher braucht Ihr Zuhause? Beginnen Sie mit den gewünschten Ersatzstromkreisen. Gespeicherte Energie, Betriebsleistung und Anlaufbedarf sind getrennte Größen. ELVORKA Produktredaktion Veröffentlicht 2026-11-05 Deutschland ![ELVORKA · Deutschland · Zu den Bildern](https://de.elvorka.com/assets/optimized/20e2f83648685da5-1536-q92.webp) Produktfreisteller zeigen die ELVORKA Markenanwendung. Lokale Installationsszenen sind mit KI unterstützte Bildmontagen mit Produkten dieser Übersicht. Sie zeigen beispielhafte Umgebungen, keine abgeschlossenen Kundeninstallationen, Empfehlungen von Kunden oder geprüften Verdrahtungen. Eine konkrete Frage erleichtert die Auslegung: Welche Geräte sollen wie lange weiterlaufen? Eine Liste ausgewählter Stromkreise hilft mehr als eine pauschale Zusage für das gesamte Haus. Die folgenden lokalen Beispiele dienen als Arbeitsblatt. Ersetzen Sie die Ansätze durch Geräte- oder Planungsdaten. ## kWh und kW beantworten verschiedene Fragen kWh beschreibt die gespeicherte Energie, kW die abgegebene Leistung. Mehr Batteriekapazität bedeutet nicht automatisch mehr AC-Ausgangsleistung. DC-Leistung der Batterie, AC-Ausgang des Wechselrichters, Anlaufbedarf und Ersatzstromkreise müssen zu den vorgesehenen Verbrauchern passen. ## Ein Arbeitsblatt für lokale Verbraucher ### Homeoffice · 200 W - Laptop-Ansatz: 80 W - Monitor: 40 W - Router: 20 W - LED-Arbeitslicht: 30 W - Kleinzubehör: 30 W ### Wichtige Haushaltsverbraucher · 400 W - Kühlschrank-Betriebsansatz: 150 W - Gefriergerät-Betriebsansatz: 100 W - Ausgewählte Beleuchtung: 60 W - Router: 20 W - Lüftung/Steuerung: 70 W ### Ausgewählter Abendstromkreis · 700 W - Kühlschrank-Ansatz: 150 W - Gefriergerät-Ansatz: 150 W - Fernseher: 100 W - Beleuchtung: 80 W - Router: 20 W - Desktop-Computer: 200 W Planungsbeispiele, keine gemessenen Verbräuche oder Laufzeitgarantien. Anlaufstrom, ersatzstromfähige Stromkreise und AC-Ausgang des Wechselrichters bestätigen. ## Eine Laufzeitschätzung mit offenen Annahmen Nur zum Vergleich: Laufzeit in Stunden = Nennenergie × angenommener nutzbarer Anteil × angenommener Umwandlungswirkungsgrad ÷ mittlere Last in kW. Hier werden 90 % nutzbare Energie und 90 % Wirkungsgrad als Planungsannahmen verwendet, nicht als Produktzusagen. Reserve, Temperatur, Alterung, Eigenverbrauch, Taktbetrieb und Wechselrichter beeinflussen das Ergebnis. ### Rechenbeispiel TR6000WX-Pro | Angenommene Last (W) | Geschätzte Laufzeit (h) | | --- | --- | | 200 | 41.5 | | 400 | 20.7 | | 700 | 11.8 | 10,24 kWh Nennenergie; Annahmen 0,90 × 0,90. Eine Berechnung, kein gemessener deutscher Haushaltsbetrieb. ## Zuerst die Systemarchitektur wählen EU 230 V und TA6000 integrieren Batterie und Wechselrichter. Für diese Grundarchitektur ist kein zweiter separater Wechselrichter vorgesehen. TR Pro, TR Standard, HP Ultra, HP K und TB sind reine Batterien und benötigen einen kompatiblen externen Wechselrichter. Spannungsfenster, Stromgrenzen, Kommunikationsprotokoll und Firmware müssen passen; gleiche Nennspannung allein genügt nicht. [Ersatzstrom-Rechner](https://de.elvorka.com/de/#planner) Nutzen Sie den Ersatzstrom-Rechner für den ersten Vergleich. Senden Sie anschließend Verbraucher, gewünschte Dauer und vorhandenen Wechselrichter mit Ihrer Anfrage. Die elektrische Planung und endgültige Kompatibilität sind für das konkrete Projekt zu bestätigen. ## Fragen an den Installateur ### Kann die Batterie in eine unbeheizte Garage? Erst nach Abgleich von Temperatur, Feuchte und Exposition mit den Vorgaben des genauen Modells. Mehrere Familien nennen Laden ab 0 °C. Heizkonfiguration und Ladeschutz bestätigen; kältere Entladegrenzen erlauben kein entsprechendes Laden. ### Kann ich eine Wärmepumpe oder einen Elektroherd absichern? Diese Verbraucher separat auslegen. Betriebsleistung und Anlauf können die Planung bestimmen; die Beispiel-Grundlasten enthalten sie nicht. DC-Leistung der Batterie sowie AC-Ausgang und Ersatzstromfähigkeit des Wechselrichters und der Stromkreise prüfen. ### Bestätigt eine 230 V-Angabe die Eignung für meine Anlage? Nein. AC-Konfiguration, Phasenanordnung, erforderliche Unterlagen, Wechselrichterkompatibilität und Installationsplanung für das konkrete Projekt bestätigen. Der Katalog belegt keine landesspezifische Zulassung. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) ## Weiterlesen Journal ## [Den Batterieplatz vor der Installation auswählen.](https://de.elvorka.com/de/blog/installation-environment/) Raumtemperatur, Feuchte, Zugang und Systemaufbau zählen mehr als ein landesweiter Klimamittelwert. [Artikel lesen](https://de.elvorka.com/de/blog/installation-environment/) Neuigkeiten ## [Originalansichten und Anschlussinformationen leichter finden.](https://de.elvorka.com/de/news/technical-library/) 35 Quellabbildungen und 97 beschriftete Merkmale verbinden Produktseiten mit der technischen Bibliothek. [Artikel lesen](https://de.elvorka.com/de/news/technical-library/) --- https://de.elvorka.com/de/blog/battery-capacity/ ELVORKA · eric@elvorka.com --- # Den Batterieplatz vor der Installation auswählen. Journal / Deutschland # Den Batterieplatz vor der Installation auswählen. Raumtemperatur, Feuchte, Zugang und Systemaufbau zählen mehr als ein landesweiter Klimamittelwert. ELVORKA Produktredaktion Veröffentlicht 2026-11-05 Deutschland ![ELVORKA · Deutschland · Zu den Bildern](https://de.elvorka.com/assets/optimized/17634903794cc9c9-1536-q92.webp) Produktfreisteller zeigen die ELVORKA Markenanwendung. Lokale Installationsszenen sind mit KI unterstützte Bildmontagen mit Produkten dieser Übersicht. Sie zeigen beispielhafte Umgebungen, keine abgeschlossenen Kundeninstallationen, Empfehlungen von Kunden oder geprüften Verdrahtungen. Ein trockener Hauswirtschaftsraum, eine sommerwarme Garage und ein küstennaher Technikbereich stellen unterschiedliche Anforderungen. Bewerten Sie die Bedingungen direkt am Batterieplatz, auch in der kältesten und wärmsten Jahreszeit. Die lokalen Profile helfen bei der Vorbereitung; sie bestätigen keine konkrete Installation. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. ### Kühler Winterstandort · Garage oder Nebengebäude Deutschland weist regionale Temperaturunterschiede auf; ein unbeheizter Technikraum ist getrennt vom bewohnten Haus zu beurteilen. Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. Fragen an den Installateur - Kann die Temperatur am Batterieplatz beim Laden unter 0 °C fallen? - Sind Heizung und Ladeschutz für das genaue Modell bestätigt? - Bleibt der Standort trocken, wenn kalte Geräte auf wärmere Luft treffen? ### Hauswirtschaftsraum im Keller · trocken und zugänglich Ein separater Hauswirtschaftsraum kann Speicher und Servicezugang ordnen. Prüfen Sie Feuchte, Lüftung und Zugang; nicht jeder Keller ist automatisch geeignet. Das EU-All-in-one vereint Wechselrichter und Batterie im IP21-Gehäuse und braucht keinen zusätzlichen Wechselrichter. Reine TR-, HP- und TB-Batterien benötigen einen kompatiblen externen Wechselrichter. Kühl- und Serviceabstände des jeweiligen Handbuchs einhalten. Fragen an den Installateur - Gibt es Feuchte, Kondensat oder bekannte Wassereintrittswege? - Bleiben Lüftung und Servicezugang frei von gelagerten Gegenständen? - Ist eine neue integrierte Anlage oder die Ergänzung eines vorhandenen Wechselrichters geplant? ### Sommerwarme Region · Wärme im Gebäude Offizielle Klimaindikatoren unterscheiden wärmere Sommerregionen, etwa Oberrhein und Rhein-Neckar/Rhein-Main. Das Gebäude beeinflusst das Raumklima zusätzlich. Erfassen Sie die höchste erwartete Temperatur am Gerät. Eine obere Ladetemperaturgrenze belegt keine volle Leistung im geschlossenen, sonnenaufgeheizten Raum. HP Ultra benötigt eine Bestätigung der Temperaturgrenzen für die Konfiguration; TR-Pro-Werte nicht übertragen. Fragen an den Installateur - Staut sich Nachmittags- oder Dachwärme im Raum? - Welche Temperatur- und Leistungsreduktionsvorgaben gelten für das genaue Modell? - Kann der Montageort den nötigen Kühlraum dauerhaft freihalten? ### Planung - Zuerst den Systemaufbau wählen: EU und TA6000 enthalten einen Wechselrichter; reine Batteriefamilien benötigen einen externen kompatiblen Wechselrichter und bestätigte Kommunikation. - Lade- und Entladetemperaturen getrennt betrachten. Optionale Heizung und das allgemeine TA6000-Betriebsfeld belegen kein universelles Laden unter null. - IP21, IP20, optionales IP54 und IP66 sind unterschiedliche Quellenangaben. Keine davon allein belegt Eignung bei Kondensat, Überflutung oder salzhaltiger Küstenluft. ## Lade- und Entladegrenzen getrennt betrachten TR Pro nennt Laden bei 0–55 °C und Entladen bei −20–60 °C. Die kältere Entladegrenze erlaubt kein Laden unter null. Selbstheizung ist optional und für die genaue Ausführung zu bestätigen. Die Temperaturgrenzen von HP Ultra müssen für die Konfiguration geklärt werden; Werte anderer Familien sind nicht übertragbar. ## Ansichten prüfen, das genaue Handbuch anfordern Die technische Bibliothek enthält Originalansichten und nummerierte Anschlussbeschriftungen. Ein sichtbarer Anschluss belegt weder Pinbelegung noch Polarität oder Leistung. Schaltplan, Schutz, Leitungen, Abstände, Drehmomente und Kommunikation sind anhand der Installationsunterlagen des gewählten Modells zu klären. Die Szenenbilder sind Anschauungsmaterial und keine Verdrahtungsanleitung. [Originalansichten & Anschlüsse](https://de.elvorka.com/de/#technical-library) Halten Sie Raum, erwartete Temperaturen, Feuchteeinwirkung und Wartungszugang fest. Bei integrierten Anlagen ist die benötigte AC-Ausführung zu bestätigen. Für reine Batterien gehören vorhandenes Wechselrichtermodell und DC-Spannungsfenster in die Anfrage. ## Fragen an den Installateur ### Kann die Batterie in eine unbeheizte Garage? Erst nach Abgleich von Temperatur, Feuchte und Exposition mit den Vorgaben des genauen Modells. Mehrere Familien nennen Laden ab 0 °C. Heizkonfiguration und Ladeschutz bestätigen; kältere Entladegrenzen erlauben kein entsprechendes Laden. ### Kann ich eine Wärmepumpe oder einen Elektroherd absichern? Diese Verbraucher separat auslegen. Betriebsleistung und Anlauf können die Planung bestimmen; die Beispiel-Grundlasten enthalten sie nicht. DC-Leistung der Batterie sowie AC-Ausgang und Ersatzstromfähigkeit des Wechselrichters und der Stromkreise prüfen. ### Bestätigt eine 230 V-Angabe die Eignung für meine Anlage? Nein. AC-Konfiguration, Phasenanordnung, erforderliche Unterlagen, Wechselrichterkompatibilität und Installationsplanung für das konkrete Projekt bestätigen. Der Katalog belegt keine landesspezifische Zulassung. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) ## Weiterlesen Journal ## [Wie viel Batteriespeicher braucht Ihr Zuhause?](https://de.elvorka.com/de/blog/battery-capacity/) Beginnen Sie mit den gewünschten Ersatzstromkreisen. Gespeicherte Energie, Betriebsleistung und Anlaufbedarf sind getrennte Größen. [Artikel lesen](https://de.elvorka.com/de/blog/battery-capacity/) Neuigkeiten ## [Die internationale ELVORKA Produktübersicht ist online.](https://de.elvorka.com/de/news/product-collection/) Sieben Produktfamilien, 29 aufgeführte Konfigurationen und sprachbezogene Produktunterlagen sind in den Länderausgaben verknüpft. [Artikel lesen](https://de.elvorka.com/de/news/product-collection/) --- https://de.elvorka.com/de/blog/installation-environment/ ELVORKA · eric@elvorka.com --- # Die internationale ELVORKA Produktübersicht ist online. Neuigkeiten / Deutschland # Die internationale ELVORKA Produktübersicht ist online. Sieben Produktfamilien, 29 aufgeführte Konfigurationen und sprachbezogene Produktunterlagen sind in den Länderausgaben verknüpft. ELVORKA Produktredaktion Veröffentlicht 2026-11-05 Deutschland ![ELVORKA · Deutschland · Zu den Bildern](https://de.elvorka.com/assets/optimized/17634903794cc9c9-1536-q92.webp) Produktfreisteller zeigen die ELVORKA Markenanwendung. Lokale Installationsszenen sind mit KI unterstützte Bildmontagen mit Produkten dieser Übersicht. Sie zeigen beispielhafte Umgebungen, keine abgeschlossenen Kundeninstallationen, Empfehlungen von Kunden oder geprüften Verdrahtungen. Die aktuelle Online-Übersicht führt die bereitgestellten Produktunterlagen im ELVORKA Auftritt zusammen. Sie umfasst integrierte Speichersysteme und reine Batterien. Solarmodule und eigenständige Wechselrichter gehören nicht zum angebotenen Sortiment. Jede Länderausgabe verbindet Modellangaben mit lokalen Fragen zum Aufstellort, beispielhaften Verbraucherlasten und einer herunterladbaren Produktübersicht. Die Sprachauswahl verknüpft entsprechende Seiten. Die englische US-Ausgabe ist der Hauptauftritt; die Länderausgaben sind direkt erreichbar. ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. ## Produkte | Produkte | Modell | Nennenergie (kWh) | | --- | --- | --- | | TR Pro | TR6000WX-Pro | 10.24 | | | TR8500WX-Pro | 16.076 | | | TR8500WX-ProU | 16.076 | | EU 230 V | 6.2K-10/16KWH-EU | 10.24 | | | 6.2K-10/16KWH-EU | 16.076 | | | 12K-16KWH-EU | 16.076 | | HP Ultra | HP Ultra-8.0 | 8 | | | HP Ultra-16.0 | 16 | | | HP Ultra-24.0 | 24 | | | HP Ultra-32.0 | 32 | | | HP Ultra-40.0 | 40 | | | HP Ultra-48.0 | 48 | | TA6000 | TA6000-M2 | 10.24 | | | TA6000-M3 | 15.36 | | | TA6000-M4 | 20.48 | | TR standard | TR4000WX | 5.12 | | | TR6000WX | 10.24 | | | TR8000WX | 14.336 | | | TR8500WX | 16.076 | | | TR10000WX | 20.07 | | HP K | HP2000K | 20.48 | | | HP2500K | 25.6 | | | HP3000K | 30.72 | | | HP3500K | 35.84 | | | HP4000K | 40.96 | | TB rack | TB4000X | 5.12 | | | TB6000X | 10.24 | | | TB8000X | 14.336 | | | TB8500X | 16.076 | ## Was die Produktübersicht belegt Die Tabellen geben die bereitgestellten Unterlagen wieder. Sie bestätigen weder lokalen Lagerbestand noch Zertifizierung, Netzfreigabe, Installateurabdeckung oder einheitliche Garantie in allen Märkten. Fragen Sie die genaue Ausführung, Unterlagen und Konditionen an. Die Installationsszenen sind Illustrationen und keine abgeschlossenen Kundenprojekte. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) ## Weiterlesen Journal ## [Wie viel Batteriespeicher braucht Ihr Zuhause?](https://de.elvorka.com/de/blog/battery-capacity/) Beginnen Sie mit den gewünschten Ersatzstromkreisen. Gespeicherte Energie, Betriebsleistung und Anlaufbedarf sind getrennte Größen. [Artikel lesen](https://de.elvorka.com/de/blog/battery-capacity/) --- https://de.elvorka.com/de/news/product-collection/ ELVORKA · eric@elvorka.com --- # Originalansichten und Anschlussinformationen leichter finden. Neuigkeiten / Deutschland # Originalansichten und Anschlussinformationen leichter finden. 35 Quellabbildungen und 97 beschriftete Merkmale verbinden Produktseiten mit der technischen Bibliothek. ELVORKA Produktredaktion Veröffentlicht 2026-11-05 Deutschland ![ELVORKA · Deutschland · Zu den Bildern](https://de.elvorka.com/assets/optimized/20e2f83648685da5-1536-q92.webp) Produktfreisteller zeigen die ELVORKA Markenanwendung. Lokale Installationsszenen sind mit KI unterstützte Bildmontagen mit Produkten dieser Übersicht. Sie zeigen beispielhafte Umgebungen, keine abgeschlossenen Kundeninstallationen, Empfehlungen von Kunden oder geprüften Verdrahtungen. Die Bibliothek enthält die bereitgestellten Vorder-, Seiten-, Rück- und Anschlussansichten. Insgesamt stehen 35 Abbildungen und 97 beschriftete Merkmale zur Verfügung. Art und Anzahl unterscheiden sich je Produktfamilie. Mit der nummerierten Auswahl wechseln Sie zwischen vorhandenen Ansichten. Anschlussnotizen ordnen die Beschriftungen den Originalunterlagen zu. Die herunterladbare Übersicht zu Ansichten und Anschlüssen bündelt das Material für die Abstimmung mit dem Installateur. [Originalansichten & Anschlüsse](https://de.elvorka.com/de/#technical-library) ## Kühler Winterstandort · Garage oder Nebengebäude Prüfen Sie die Ladegrenzen der genauen Familie vor der Standortwahl. TR Pro nennt Laden 0 bis 55 °C und Entladen −20 bis 60 °C. Optionale Selbstheizung muss für die Konfiguration bestätigt werden; die tiefere Entladegrenze erlaubt kein Laden unter null. [TR Pro ↗](https://de.elvorka.com/de/products/tr-pro/#technical-views)[EU 230 V ↗](https://de.elvorka.com/de/products/eu-230v/#technical-views)[HP Ultra ↗](https://de.elvorka.com/de/products/hp-ultra/#technical-views)[TA6000 ↗](https://de.elvorka.com/de/products/ta6000/#technical-views)[TR standard ↗](https://de.elvorka.com/de/products/tr-standard/#technical-views)[HP K ↗](https://de.elvorka.com/de/products/hp-k/#technical-views)[TB rack ↗](https://de.elvorka.com/de/products/tb-rack/#technical-views) ## Was die Produktübersicht belegt Die Abbildungen helfen bei der Produktidentifikation. Sie belegen keine undokumentierte Pinbelegung oder lokale Installationskonformität und ersetzen kein aktuelles Modellhandbuch. Lassen Sie unklare Anschlussfunktionen und Ausführungen bestätigen. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) ## Weiterlesen Journal ## [Wie viel Batteriespeicher braucht Ihr Zuhause?](https://de.elvorka.com/de/blog/battery-capacity/) Beginnen Sie mit den gewünschten Ersatzstromkreisen. Gespeicherte Energie, Betriebsleistung und Anlaufbedarf sind getrennte Größen. [Artikel lesen](https://de.elvorka.com/de/blog/battery-capacity/) Neuigkeiten ## [Die internationale ELVORKA Produktübersicht ist online.](https://de.elvorka.com/de/news/product-collection/) Sieben Produktfamilien, 29 aufgeführte Konfigurationen und sprachbezogene Produktunterlagen sind in den Länderausgaben verknüpft. [Artikel lesen](https://de.elvorka.com/de/news/product-collection/) --- https://de.elvorka.com/de/news/technical-library/ ELVORKA · eric@elvorka.com --- # Heimspeicher. Klar beschrieben. ELVORKA / Deutschland # Heimspeicher. Klar beschrieben. ELVORKA stellt integrierte Speichersysteme und reine Batterien für private Energieprojekte vor. Im Mittelpunkt stehen das Gerät, sein Aufstellraum und die zu versorgenden Verbraucher. ELVORKA stellt integrierte Speichersysteme und reine Batterien für private Energieprojekte vor. Im Mittelpunkt stehen das Gerät, sein Aufstellraum und die zu versorgenden Verbraucher. Vergleichen Sie dokumentierte Modelle, prüfen Sie Originalansichten und bereiten Sie Ihre Projektanfrage in der passenden Sprachausgabe vor. Die Länderinhalte berücksichtigen lokale Bedingungen, ohne einem ganzen Land ein einziges Klima oder eine einheitliche elektrische Ausführung zuzuschreiben. ## Zuerst die Systemarchitektur wählen EU 230 V und TA6000 integrieren Batterie und Wechselrichter. Für diese Grundarchitektur ist kein zweiter separater Wechselrichter vorgesehen. TR Pro, TR Standard, HP Ultra, HP K und TB sind reine Batterien und benötigen einen kompatiblen externen Wechselrichter. Spannungsfenster, Stromgrenzen, Kommunikationsprotokoll und Firmware müssen passen; gleiche Nennspannung allein genügt nicht. ## Nach dem Technikraum wählen, nicht nach dem Landesmittel. Eine kühlere Garage in Höhenlage, ein trockener Hauswirtschaftsraum im Keller und ein sommerwarmer Raum am Rhein stellen unterschiedliche Anforderungen. Entscheidend sind Temperatur und Exposition am Batterieplatz. ## So funktionieren Anfragen Das Formular übermittelt Ihre Angaben an das geschützte ELVORKA Projektpostfach. Dort werden sie zur Bearbeitung gespeichert und dem autorisierten mobilen Arbeitskonto bereitgestellt. Markt, Sprache, Seite und gemeldete Referrer-/UTM-Hinweise werden mitgesendet; die IP-Ortung ist ungenau. Erste und letzte Herkunftshinweise bleiben in der Browsersitzung und werden nur mit einer Anfrage übertragen. Eine Farbeinstellung kann lokal gespeichert werden. Eine lokale Kopie und E-Mail an eric@elvorka.com bleiben möglich. Cloudflare liefert die Seiten aus. ## Was die Produktübersicht belegt Die Tabellen geben die bereitgestellten Unterlagen wieder. Sie bestätigen weder lokalen Lagerbestand noch Zertifizierung, Netzfreigabe, Installateurabdeckung oder einheitliche Garantie in allen Märkten. Fragen Sie die genaue Ausführung, Unterlagen und Konditionen an. Die Installationsszenen sind Illustrationen und keine abgeschlossenen Kundenprojekte. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) --- https://de.elvorka.com/de/about/ ELVORKA · eric@elvorka.com --- # Klare Quellen. Erkennbare Grenzen. ELVORKA / Deutschland # Klare Quellen. Erkennbare Grenzen. Modellangaben stammen aus den bereitgestellten Unterlagen zu Heimspeichern und integrierten EU-Systemen. Regionale Hinweise nutzen die unten verlinkten öffentlichen Quellen. Planungsannahmen und Illustrationen werden gesondert bezeichnet. Modellangaben stammen aus den bereitgestellten Unterlagen zu Heimspeichern und integrierten EU-Systemen. Regionale Hinweise nutzen die unten verlinkten öffentlichen Quellen. Planungsannahmen und Illustrationen werden gesondert bezeichnet. ## Produktgrundlagen Modelltabellen, Originalabbildungen und beschriftete Anschlussinformationen bilden die Produktgrundlage dieser Website. Angaben können je Modell und Ausführung variieren. Vor Kauf und Installation bleiben das aktuelle Handbuch, die Kompatibilitätsbestätigung und die Projektunterlagen erforderlich. [Originalansichten & Anschlüsse](https://de.elvorka.com/de/#technical-library) ## Zu den Bildern Produktfreisteller zeigen die ELVORKA Markenanwendung. Lokale Installationsszenen sind mit KI unterstützte Bildmontagen mit Produkten dieser Übersicht. Sie zeigen beispielhafte Umgebungen, keine abgeschlossenen Kundeninstallationen, Empfehlungen von Kunden oder geprüften Verdrahtungen. ## Quellen zum regionalen Umfeld - [Klimastatusbericht 2024: Regionale Vielfalt des Klimas in Deutschland](https://www.dwd.de/DE/leistungen/klimastatusbericht/publikationen/ksb_2024.pdf?__blob=publicationFile&v=4) - [BAU-I-3: Cooling degree days](https://www.umweltbundesamt.de/en/monitoring-on-das/cluster/building-industry/bau-i-3/indicator) ## Für Menschen und Software lesbar Die öffentlichen Produktinformationen sind als HTML, Markdown und strukturierter Katalog verfügbar. Diese Formate erleichtern Abruf und Quellenangabe; sie ergänzen keine Leistungs-, Zertifizierungs- oder versteckten Aussagen. Zitieren Sie die kanonische Seite mit ihren modellspezifischen Einschränkungen. - [llms.txt](https://de.elvorka.com/llms.txt) - [llms-full.txt](https://de.elvorka.com/llms-full.txt) - [JSON · Produkte](https://de.elvorka.com/data/product-catalogue.json) Bei Unklarheiten oder Korrekturen schreiben Sie an eric@elvorka.com und nennen Sie Modell, Seite und betreffende Quelle. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projektanfrage senden](https://de.elvorka.com/de/contact/) --- https://de.elvorka.com/de/sources/ ELVORKA · eric@elvorka.com --- # Planen wir Ihr Speicherprojekt. ELVORKA / Deutschland # Planen wir Ihr Speicherprojekt. Beschreiben Sie Aufstellort, gewünschte Verbraucher und Produktinteresse. Ihre Anfrage wird im ELVORKA Projektpostfach erfasst. Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [eric@elvorka.com](mailto:eric@elvorka.com) [Gesamtes Sortiment ansehen](https://de.elvorka.com/de/#products) [Produktübersicht herunterladen](https://de.elvorka.com/downloads/ELVORKA_de_de_Product_Guide.pdf) Ihr Name (optional) Projektort * Ihre E-Mail-Adresse Telefon / WhatsApp (optional, mit Ländervorwahl) Unternehmen (optional) Ich plane für Vorhandener Wechselrichter Produktinteresse Was ist Ihnen wichtig? Region und saisonale Exposition Niedrigste / höchste beobachtete Raumtemperatur AC-Versorgung und benötigte Phasenanordnung Ihre Angaben werden für die Prüfung und weitere Bearbeitung durch ELVORKA gespeichert. Bitte keine Passwörter, Ausweisdokumente oder sachfremden sensiblen Informationen eintragen. ELVORKA darf diese Angaben zur Bearbeitung und Beantwortung meiner Projektanfrage verwenden. ## Projektanfragen Nennen Sie Standort, gewünschte Ersatzstromkreise, Batteriemodell und Aufstellbedingungen. Verfügbarkeit, elektrische Ausführung und Projektanforderungen klären wir auf Anfrage. [Projekt per E-Mail anfragen ↗](mailto:eric@elvorka.com) --- https://de.elvorka.com/de/contact/ ELVORKA · eric@elvorka.com --- # A clearer view of home storage. Journal / Deutschland # A clearer view of home storage. Practical reading for choosing battery capacity, checking equipment-room conditions and preparing a useful installation brief. Journal ## [How much battery storage does your home need?](https://de.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://de.elvorka.com/en/blog/battery-capacity/) Journal ## [Choose the battery location before installation.](https://de.elvorka.com/en/blog/installation-environment/) Room temperature, moisture, access and system architecture matter more than a national climate average. [Read article](https://de.elvorka.com/en/blog/installation-environment/) ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) --- https://de.elvorka.com/en/blog/ ELVORKA · eric@elvorka.com --- # Inside the ELVORKA collection. News / Deutschland # Inside the ELVORKA collection. Published product resources and website updates, with a clear distinction between documented specifications and project-specific requirements. News ## [The international ELVORKA product collection is available online.](https://de.elvorka.com/en/news/product-collection/) Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. [Read article](https://de.elvorka.com/en/news/product-collection/) News ## [Original product views and interface notes are now easier to explore.](https://de.elvorka.com/en/news/technical-library/) 35 source figures and 97 labelled features connect the product pages to a more detailed technical library. [Read article](https://de.elvorka.com/en/news/technical-library/) ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) --- https://de.elvorka.com/en/news/ ELVORKA · eric@elvorka.com --- # How much battery storage does your home need? Journal / Deutschland # How much battery storage does your home need? Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. ELVORKA Product Desk Published 2026-11-05 Deutschland ![ELVORKA · Deutschland · About the images](https://de.elvorka.com/assets/optimized/20e2f83648685da5-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. A battery is easier to size when the question is specific: which appliances should keep running, and for how long? A list of selected circuits is more useful than a promise of whole-home backup. Use the local examples below as a starting worksheet, then replace every assumption with appliance or installer data. ## kWh and kW answer different questions Energy in kWh describes the amount stored. Power in kW describes how quickly energy is delivered. A larger battery does not automatically provide a higher AC output. Battery-side DC ratings, inverter AC output, starting demand and the backup-circuit arrangement must all support the intended loads. ## A local load worksheet ### Home office · 200 W - Laptop allowance: 80 W - Monitor: 40 W - Router: 20 W - LED task lighting: 30 W - Small accessories: 30 W ### Household essentials · 400 W - Refrigerator running allowance: 150 W - Freezer running allowance: 100 W - Selected lighting: 60 W - Router: 20 W - Ventilation/control allowance: 70 W ### Selected evening circuit · 700 W - Refrigerator allowance: 150 W - Freezer allowance: 150 W - Television: 100 W - Lighting: 80 W - Router: 20 W - Desktop computer: 200 W These are planning examples, not measured usage or guaranteed runtime. Confirm starting current, backup-capable circuits and the selected inverter's AC output. ## An indicative runtime, with assumptions visible For comparison only: runtime in hours = nominal battery energy × assumed usable fraction × assumed conversion efficiency ÷ average load in kW. The example uses 90% usable energy and 90% conversion efficiency as planning assumptions, not product guarantees. Actual runtime also depends on reserve settings, temperature, ageing, standby consumption, duty cycles and the selected inverter. ### Illustrative TR6000WX-Pro example | Assumed load (W) | Indicative runtime (h) | | --- | --- | | 200 | 41.5 | | 400 | 20.7 | | 700 | 11.8 | 10.24 kWh nominal energy; assumptions 0.90 × 0.90. This is a calculation, not a tested local household result. ## Choose the architecture before the capacity EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility. [Backup explorer](https://de.elvorka.com/en/#planner) Use the backup explorer for a first comparison, then send the selected loads, required duration and existing inverter details with your enquiry. Electrical design and final compatibility need to be confirmed for the actual project. ## Questions for your installer ### Can the battery go in an unheated garage? Only after checking the actual temperature, damp and exposure against the exact model's instructions. Several families list charging from 0 °C. Confirm any heating configuration and charge protection; colder discharge limits are not charging permission. ### Can I back up a heat pump or electric cooker? Assess those loads separately. Their running power and starting requirements can dominate the design; the example essential-load totals do not include them. Confirm both battery DC capability and inverter AC and backup-circuit capability. ### Does a 230 V product listing confirm suitability for my installation? No. Confirm the selected AC configuration, phase arrangement, required documentation, inverter compatibility and installation design for the actual project. The catalogue does not establish country-specific approval. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) ## Continue exploring Journal ## [Choose the battery location before installation.](https://de.elvorka.com/en/blog/installation-environment/) Room temperature, moisture, access and system architecture matter more than a national climate average. [Read article](https://de.elvorka.com/en/blog/installation-environment/) News ## [Original product views and interface notes are now easier to explore.](https://de.elvorka.com/en/news/technical-library/) 35 source figures and 97 labelled features connect the product pages to a more detailed technical library. [Read article](https://de.elvorka.com/en/news/technical-library/) --- https://de.elvorka.com/en/blog/battery-capacity/ ELVORKA · eric@elvorka.com --- # Choose the battery location before installation. Journal / Deutschland # Choose the battery location before installation. Room temperature, moisture, access and system architecture matter more than a national climate average. ELVORKA Product Desk Published 2026-11-05 Deutschland ![ELVORKA · Deutschland · About the images](https://de.elvorka.com/assets/optimized/17634903794cc9c9-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. A dry utility room, a seasonally hot garage and a coastal service area place different demands on equipment. Assess conditions where the battery will stand, including the coldest and hottest periods. The following local profiles help frame the questions; they do not certify a particular installation. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. ## Choose for the equipment room, not a national average. ### Cooler winter location · garage or outbuilding Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home. Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. Questions for your installer - Can the battery position fall below 0 °C during charging? - Will the selected heating and charging protections be confirmed for this exact model? - Does the location remain dry when cold equipment meets warmer air? ### Basement utility room · dry and accessible A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable. The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space. Questions for your installer - Is there damp, condensation or a known water-entry route? - Are ventilation and service access clear of storage items? - Is this a new integrated installation or an addition to an existing inverter? ### Warmer summer region · indoor heat Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions. Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it. Questions for your installer - Does the room accumulate afternoon or roof heat? - What are the exact model's temperature and output derating requirements? - Can the proposed mounting position maintain the required cooling space? ### Planning notes - Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication. - Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging. - IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability. ## Keep charging and discharging limits separate The TR Pro literature lists charging at 0–55 °C and discharging at −20–60 °C. The colder discharge boundary is not permission to charge below zero. Self-heating is optional and must be confirmed for the exact configuration. HP Ultra temperature limits require configuration confirmation; do not transfer another family's limits to it. ## Read the views, then request the exact manual The technical library retains the original product views and numbered interface labels. A visible connector is not enough to infer a pinout, polarity or power rating. Confirm the selected model's wiring diagram, protection, cable requirements, clearances, torque values and communication settings from its installation documentation. The scene illustrations are visual references, not wiring instructions. [Original views & interfaces](https://de.elvorka.com/en/#technical-library) Record the proposed room, expected temperatures, moisture exposure and maintenance access. For an integrated system, confirm the required AC configuration. For a battery-only system, include the existing inverter model and DC voltage range in the brief. ## Questions for your installer ### Can the battery go in an unheated garage? Only after checking the actual temperature, damp and exposure against the exact model's instructions. Several families list charging from 0 °C. Confirm any heating configuration and charge protection; colder discharge limits are not charging permission. ### Can I back up a heat pump or electric cooker? Assess those loads separately. Their running power and starting requirements can dominate the design; the example essential-load totals do not include them. Confirm both battery DC capability and inverter AC and backup-circuit capability. ### Does a 230 V product listing confirm suitability for my installation? No. Confirm the selected AC configuration, phase arrangement, required documentation, inverter compatibility and installation design for the actual project. The catalogue does not establish country-specific approval. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) ## Continue exploring Journal ## [How much battery storage does your home need?](https://de.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://de.elvorka.com/en/blog/battery-capacity/) News ## [The international ELVORKA product collection is available online.](https://de.elvorka.com/en/news/product-collection/) Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. [Read article](https://de.elvorka.com/en/news/product-collection/) --- https://de.elvorka.com/en/blog/installation-environment/ ELVORKA · eric@elvorka.com --- # The international ELVORKA product collection is available online. News / Deutschland # The international ELVORKA product collection is available online. Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. ELVORKA Product Desk Published 2026-11-05 Deutschland ![ELVORKA · Deutschland · About the images](https://de.elvorka.com/assets/optimized/17634903794cc9c9-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. The current online collection brings the supplied product literature into a common ELVORKA format. It covers integrated storage systems and battery-only families. Solar panels and standalone inverters are not products offered in this collection. Each market edition combines model specifications, local installation-environment questions, illustrative appliance loads and a downloadable product guide. The language selector keeps equivalent pages connected. The United States English edition is the main website; dedicated country editions remain directly accessible. ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. ## Products | Products | Model | Nominal energy (kWh) | | --- | --- | --- | | TR Pro | TR6000WX-Pro | 10.24 | | | TR8500WX-Pro | 16.076 | | | TR8500WX-ProU | 16.076 | | EU 230 V | 6.2K-10/16KWH-EU | 10.24 | | | 6.2K-10/16KWH-EU | 16.076 | | | 12K-16KWH-EU | 16.076 | | HP Ultra | HP Ultra-8.0 | 8 | | | HP Ultra-16.0 | 16 | | | HP Ultra-24.0 | 24 | | | HP Ultra-32.0 | 32 | | | HP Ultra-40.0 | 40 | | | HP Ultra-48.0 | 48 | | TA6000 | TA6000-M2 | 10.24 | | | TA6000-M3 | 15.36 | | | TA6000-M4 | 20.48 | | TR standard | TR4000WX | 5.12 | | | TR6000WX | 10.24 | | | TR8000WX | 14.336 | | | TR8500WX | 16.076 | | | TR10000WX | 20.07 | | HP K | HP2000K | 20.48 | | | HP2500K | 25.6 | | | HP3000K | 30.72 | | | HP3500K | 35.84 | | | HP4000K | 40.96 | | TB rack | TB4000X | 5.12 | | | TB6000X | 10.24 | | | TB8000X | 14.336 | | | TB8500X | 16.076 | ## What the collection establishes The model tables reproduce supplied literature. They are not a statement of local stock, certification, grid approval, installer coverage or a standard warranty in every market. Request the exact configuration, documents and commercial terms for your project. Installation scenes are branded illustrations, not evidence of completed customer installations. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) ## Continue exploring Journal ## [How much battery storage does your home need?](https://de.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://de.elvorka.com/en/blog/battery-capacity/) --- https://de.elvorka.com/en/news/product-collection/ ELVORKA · eric@elvorka.com --- # Original product views and interface notes are now easier to explore. News / Deutschland # Original product views and interface notes are now easier to explore. 35 source figures and 97 labelled features connect the product pages to a more detailed technical library. ELVORKA Product Desk Published 2026-11-05 Deutschland ![ELVORKA · Deutschland · About the images](https://de.elvorka.com/assets/optimized/20e2f83648685da5-1536-q92.webp) Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. The product library includes the source material's front, side, rear and interface illustrations where supplied. The set contains 35 figures and 97 labelled features across the collection; the number and kind of views vary by family. Use the numbered view selector to move between available illustrations. Interface notes identify labels found in the supplied material and preserve their source context. The downloadable views-and-interfaces guide provides a consolidated reference for discussion with an installer. [Original views & interfaces](https://de.elvorka.com/en/#technical-library) ## Cooler winter location · garage or outbuilding Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging. [TR Pro ↗](https://de.elvorka.com/en/products/tr-pro/#technical-views)[EU 230 V ↗](https://de.elvorka.com/en/products/eu-230v/#technical-views)[HP Ultra ↗](https://de.elvorka.com/en/products/hp-ultra/#technical-views)[TA6000 ↗](https://de.elvorka.com/en/products/ta6000/#technical-views)[TR standard ↗](https://de.elvorka.com/en/products/tr-standard/#technical-views)[HP K ↗](https://de.elvorka.com/en/products/hp-k/#technical-views)[TB rack ↗](https://de.elvorka.com/en/products/tb-rack/#technical-views) ## What the collection establishes These figures improve product identification. They do not establish an undocumented pinout, prove an installation complies with local rules, or replace the selected model's current installation manual. Ask for confirmation whenever a connector function or configuration is not explicitly documented. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) ## Continue exploring Journal ## [How much battery storage does your home need?](https://de.elvorka.com/en/blog/battery-capacity/) Start with the circuits you want to keep running. Separate stored energy, running power and starting loads before choosing a battery. [Read article](https://de.elvorka.com/en/blog/battery-capacity/) News ## [The international ELVORKA product collection is available online.](https://de.elvorka.com/en/news/product-collection/) Seven product families, 29 listed configurations and language-specific product guides, now linked from the market editions. [Read article](https://de.elvorka.com/en/news/product-collection/) --- https://de.elvorka.com/en/news/technical-library/ ELVORKA · eric@elvorka.com --- # Home storage. Clearly specified. ELVORKA / Deutschland # Home storage. Clearly specified. ELVORKA presents integrated storage systems and battery-only products for residential energy projects. The collection is organised around the equipment, the room it will occupy and the loads it needs to support. ELVORKA presents integrated storage systems and battery-only products for residential energy projects. The collection is organised around the equipment, the room it will occupy and the loads it needs to support. Compare the documented models, inspect the original technical views and prepare a project brief in the language edition most useful to you. Market pages address local installation conditions without treating an entire country as one climate or one electrical configuration. ## Choose the architecture before the capacity EU 230 V and TA6000 are integrated battery-and-inverter families. A second standalone inverter is not part of their basic product architecture. TR Pro, TR standard, HP Ultra, HP K and TB are batteries that need a compatible external inverter. Match voltage range, current limits, communication protocol and firmware; nominal voltage alone does not establish compatibility. ## Choose for the equipment room, not a national average. A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration. ## How enquiries work The enquiry form sends the details you choose to provide to the protected ELVORKA project desk, where they are saved for review and follow-up and made available to the authorised mobile work inbox. The submission includes its market, language, page and reported referral/UTM source; IP location is approximate. First/latest visit source notes are held in this browser session and sent only with an enquiry. A colour preference may be stored locally. You can also save a local copy or contact eric@elvorka.com by email. Pages are delivered through Cloudflare. ## What the collection establishes The model tables reproduce supplied literature. They are not a statement of local stock, certification, grid approval, installer coverage or a standard warranty in every market. Request the exact configuration, documents and commercial terms for your project. Installation scenes are branded illustrations, not evidence of completed customer installations. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) --- https://de.elvorka.com/en/about/ ELVORKA · eric@elvorka.com --- # Clear sources. Visible limits. ELVORKA / Deutschland # Clear sources. Visible limits. Model facts are taken from the supplied residential storage and EU integrated-system literature. Regional environment notes use the public sources linked below. Planning assumptions and visual illustrations are identified separately. Model facts are taken from the supplied residential storage and EU integrated-system literature. Regional environment notes use the public sources linked below. Planning assumptions and visual illustrations are identified separately. ## Product evidence The product tables, original technical figures and labelled interface notes are the primary reference set for this website. Specifications can vary by exact model and configuration. The current installation manual, compatibility confirmation and project documents remain necessary before purchase or installation. [Original views & interfaces](https://de.elvorka.com/en/#technical-library) ## About the images Product cutouts carry the ELVORKA brand application. Local installation scenes are AI-assisted composites featuring products from this collection. They are illustrative environments, not photographs of completed customer projects, customer endorsements or validated wiring designs. ## Regional context sources - [Klimastatusbericht 2024: Regionale Vielfalt des Klimas in Deutschland](https://www.dwd.de/DE/leistungen/klimastatusbericht/publikationen/ksb_2024.pdf?__blob=publicationFile&v=4) - [BAU-I-3: Cooling degree days](https://www.umweltbundesamt.de/en/monitoring-on-das/cluster/building-industry/bau-i-3/indicator) ## Readable by people and software The same public product information is available as HTML, Markdown and a structured catalogue. These formats support accurate retrieval and citation; they do not add claims, certifications or hidden content. Prefer the linked canonical page and its model-specific qualifications when quoting a specification. - [llms.txt](https://de.elvorka.com/llms.txt) - [llms-full.txt](https://de.elvorka.com/llms-full.txt) - [JSON · Products](https://de.elvorka.com/data/product-catalogue.json) For a specification clarification or correction, contact eric@elvorka.com and identify the model, page and source in question. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Submit project enquiry](https://de.elvorka.com/en/contact/) --- https://de.elvorka.com/en/sources/ ELVORKA · eric@elvorka.com --- # Let’s plan your storage project. ELVORKA / Deutschland # Let’s plan your storage project. Tell us where the system will be installed, the loads you want to support and the product you are considering. Your enquiry goes to the ELVORKA project desk. Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [eric@elvorka.com](mailto:eric@elvorka.com) [Explore the full collection](https://de.elvorka.com/en/#products) [Download product guide](https://de.elvorka.com/downloads/ELVORKA_de_en_Product_Guide.pdf) Your name (optional) Project city * Your email Phone / WhatsApp (optional, include country code) Company (optional) I am planning for Existing inverter Product interest What matters to you? Region and seasonal exposure Lowest / highest observed equipment-room temperature AC supply and required phase arrangement Your submitted details are saved for the ELVORKA team to review and follow up. Please avoid including passwords, identity documents or unrelated sensitive information. I agree that ELVORKA may use these details to respond to this project enquiry. ## Project enquiries Share your city, selected circuits, battery model and installation environment. Availability, electrical configuration and project requirements are confirmed by enquiry. [Email your project ↗](mailto:eric@elvorka.com) --- https://de.elvorka.com/en/contact/ ELVORKA · eric@elvorka.com