# HP Ultra.

![HP Ultra](https://de.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp)

High-voltage battery

# HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66 / aluminium alloy

NOMINAL ENERGY  8–48 kWh

BATTERY VOLTAGE  Confirm selected configuration

[Start your project ↗](https://de.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Max. DC (kW) |
| --- | --- | --- |
| HP Ultra-8.0 | 8 | 4 |
| HP Ultra-16.0 | 16 | 8 |
| HP Ultra-24.0 | 24 | 12 |
| HP Ultra-32.0 | 32 | 16 |
| HP Ultra-40.0 | 40 | 20 |
| HP Ultra-48.0 | 48 | 24 |

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 |
| HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 |
| HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 |
| HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 |
| HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 |
| HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 |

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

## Choose for the equipment room, not a national average.

A cooler garage in an upland location, a dry basement utility room and a summer-warm room in the Rhine region need different checks. Use the temperature and exposure at the battery position to narrow the configuration.

Temperature:  Confirm selected configuration

ENCLOSURE  IP66 / aluminium alloy

01

### Cooler winter location · garage or outbuilding

Germany has regional temperature differences; an unheated equipment room must be assessed separately from the occupied home.

Compare the exact family's charging limits before choosing the placement. TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C. Optional self-heating needs configuration confirmation; the lower discharge boundary is not permission for subzero charging.

Can the battery position fall below 0 °C during charging?

- Will the selected heating and charging protections be confirmed for this exact model?

- Does the location remain dry when cold equipment meets warmer air?

02

### Basement utility room · dry and accessible

A dedicated Hauswirtschaftsraum can organise storage and service access; assess actual damp, ventilation and access rather than assuming every basement is suitable.

The EU all-in-one combines inverter and battery in an IP21 housing; it needs no extra inverter. Battery-only TR, HP or TB families require a compatible external inverter. Preserve the selected manual's ventilation and service space.

Is there damp, condensation or a known water-entry route?

- Are ventilation and service access clear of storage items?

- Is this a new integrated installation or an addition to an existing inverter?

03

### Warmer summer region · indoor heat

Official climate indicators identify warmer summer areas including the Upper Rhine and Rhine-Neckar/Rhine-Main regions; the building can further change equipment-room conditions.

Record the warmest expected temperature at the unit. A listed charging upper limit does not establish full-power operation in an enclosed sun-heated room. HP Ultra temperature limits must be confirmed for the selected configuration; do not copy TR Pro's limits onto it.

Does the room accumulate afternoon or roof heat?

- What are the exact model's temperature and output derating requirements?

- Can the proposed mounting position maintain the required cooling space?

Specifications

- Choose architecture first: EU and TA6000 include an inverter; battery-only families require an external compatible inverter and confirmed communication.

- Keep charging and discharging temperatures separate. Optional heating and the TA6000 general operating field do not establish universal subzero charging.

- IP21, IP20, optional IP54 and IP66 are distinct source ratings. None by itself establishes condensation, flooding or coastal salt-spray suitability.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

[![DC electrical / heatsink face - original callouts](https://de.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://de.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)

DC electrical / heatsink face - original callouts  DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.

[![Communication and parallel-interface face - original callouts](https://de.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://de.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)

Communication and parallel-interface face - original callouts  Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.

[![Communication-side detail (partial oblique view)](https://de.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://de.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)

Communication-side detail (partial oblique view)  Oblique detail of the stack's communication-side connector area.

[![Module top / mating surfaces](https://de.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://de.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)

Module top / mating surfaces  Battery module top and mating surfaces.

### Know your interfaces.

#### Power connections

Positive Pole  Positive terminal identified by the original leader line on the electrical face.

Negative Pole  Negative terminal identified by the original leader line on the electrical face.

#### Communication

Bluetooth/WIFI Antenna  Antenna label on the upper communication-side area.

Backup Com  The brochure labels this connection 'Backup Com' but does not explain its exact role.

INV CAN/RS485 Com  The INV-labelled CAN/RS485 communication connection shown in the original diagram.

Parallel COM1  First parallel-communication label near the lower part of the illustrated interface face.

Parallel COM2  Second parallel-communication label near the lower part of the illustrated interface face.

#### Controls & indicators

Switch  Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.

DC Breaker  DC breaker on the electrical / heatsink face.

Breathing Light  Light strip called out at the upper front portion in the oblique construction view.

#### Structure & mounting

Heat Dissipation Aluminum Plate  Heat-dissipation aluminum plate called out on the slim electrical-side illustration.

Wall Mounted Bracket  Mounting brackets shown on the vent-side illustration.

PDU  PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.

Module  Repeated battery sections below the top PDU.

Base  Base at the bottom of the illustrated stack.

BMS Debugging Interface  BMS debugging interface identified on the communication-side illustration.

Pressure Relief Valve  Pressure-relief component called out in the communication-side oblique view.

GND  Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10

---